Evaluation and clinical application of an accurate isotope dilution liquid chromatography-tandem mass spectrometry method for serum glycocholic acid
Clinica Chimica Acta · 2026-07 · 589 · 121024
DOI: 10.1016/j.cca.2026.121024 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Clinica Chimica Acta, 2026-07. Verfasst von Zhonggan Jin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Center for Clinical Laboratory, Shanghai 200126, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Glycocholic Acid. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Shanghai Municipal Health Commission.
Abstract (Originalsprache)
OBJECTIVES Glycocholic acid (GCA) is an important identified biomarker for various hepatobiliary diseases. Accurate measurement of GCA is essential for diagnosis and treatment of hepatobiliary diseases. Our aim was to develop and validate a high accuracy method for the quantification of GCA in serum. METHODS An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC/MS/MS) method has been developed and validated. The assay validation was performed, including imprecision, trueness, matrix effects, linearity, interference, and carry-over, etc. Furthermore, the developed method was applied to comparison with three latex-enhanced immunoturbidimetric assays and for external quality assessment (EQA) of clinical systems. RESULTS Excellent linearity coefficients (R2 = 0.9998) were obtained in the range from 0.063 to 49.53 μg/g. The limit of detection and limit of quantification were 0.1 ng/mL and 2.3 ng/mL, respectively. The total imprecisions were below 2.33% for low, medium, and high concentration samples. Good recoveries were achieved at three spiked levels (98.94% - 101.80%), and a relative expanded uncertainty was < 3% (k = 2). No interference, matrix effects, or carry-over were observed. Significant bias across routine GCA assays obtained by immunoassays and ID-LC/MS/MS method highlighted the urgency of standardization for the measurement of GCA. CONCLUSIONS This study successfully established an accurate quantitative method for detecting serum GCA using ID-LC/MS/MS. The method could serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials. It could support EQA management for GCA testing and promote GCA standardization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shanghai Center for Clinical Laboratory, Shanghai 200126, China.
- Department of Clinical Laboratory, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120, China.
- School of Medical Technology, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China.
- Shanghai Center for Clinical Laboratory, Shanghai 200126, China. Electronic address: jianglingli@sccl.org.cn.
- Shanghai Center for Clinical Laboratory, Shanghai 200126, China. Electronic address: juyi@sccl.org.cn.
Förderung
- Shanghai Municipal Health Commission
Zitieren
APA
Jin, Z., Ou, Y., Zong, M., Ye, Z., Li, Z., Zhang, S., Sun, H., Fan, X., Luo, X., Jiang, L., & Ju, Y. (2026). Evaluation and clinical application of an accurate isotope dilution liquid chromatography-tandem mass spectrometry method for serum glycocholic acid. Clinica Chimica Acta, 589, 121024. https://doi.org/10.1016/j.cca.2026.121024
Vancouver
Jin Z, Ou Y, Zong M, Ye Z, Li Z, Zhang S, et al. Evaluation and clinical application of an accurate isotope dilution liquid chromatography-tandem mass spectrometry method for serum glycocholic acid. Clinica Chimica Acta. 2026;589:121024. doi:10.1016/j.cca.2026.121024
BibTeX
@article{Jin2026,
author = {Jin, Zhonggan and Ou, Yuanzhu and Zong, Ming and Ye, Zhihan and Li, Zhizheng and Zhang, Sujie and Sun, Hewei and Fan, Xiaoyu and Luo, Xialin and Jiang, Lingli and Ju, Yi},
title = {Evaluation and clinical application of an accurate isotope dilution liquid chromatography-tandem mass spectrometry method for serum glycocholic acid},
journal = {Clinica Chimica Acta},
year = {2026},
volume = {589},
pages = {121024},
doi = {10.1016/j.cca.2026.121024}
}
EUVIMED