A candidate reference measurement procedure for quantification of glycocholic acid in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05449-9 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Pingping Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Glycocholic Acid. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Autobio Diagnostics Co,Ltd. ZhengZhou,China..
Abstract (Originalsprache)
Accurate measurement of serum glycocholic acid (GCA) is crucial for evaluating the activity of chronic hepatitis. Moreover, GCA is a novel identified biomarker for hepatocellular carcinoma. Although some laboratories have used the liquid chromatography-tandem mass spectrometry (LC–MS/MS) method to measure GCA in recent years, the problem of potential interference of GCA analogues has not been solved well yet. Neither reference measurement procedures nor reference materials for GCA have been listed in the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. For standardization of GCA, it is urgent to establish a candidate measurement procedure for GCA. In this study, a candidate reference measurement procedure for the quantification of GCA in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS) by a two-step sample pretreatment of protein precipitation and MAX solid-phase extraction was developed and validated. GCA can be completely separated from its structural analogues with gradient elution in 9 min compared with short time gradients published in previous literature by Huang’s group. Method validation indicated perfect quantitation precision with intra-day and inter-day values that were ≤1.30% and ≤1.80%, respectively. The method showed excellent linearity with high regression coefficients ( R 2 > 0.999) over a range of 0.92 ng/g–38.38 μg/g and perfect recoveries at three spiked levels (99.87–100.43%). No interference, matrix effect, and carryover were observed. Moreover, the cRMP was successfully applied to measure GCA in serum samples and compared with two immunoassays in a clinical laboratory. As a candidate reference method, this method can promote a GCA standardization program. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
- Department of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, Jiangsu, China.
- Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China. hanyanlin@autobio.com.cn.
Förderung
- Autobio Diagnostics Co,Ltd. ZhengZhou,China.
Zitieren
APA
Zhang, P., Wang, H., Liang, M., Wang, Z., Liu, C., & Han, Y. (2024). A candidate reference measurement procedure for quantification of glycocholic acid in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05449-9
Vancouver
Zhang P, Wang H, Liang M, Wang Z, Liu C, Han Y. A candidate reference measurement procedure for quantification of glycocholic acid in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05449-9
BibTeX
@article{Zhang2024,
author = {Zhang, Pingping and Wang, Huimin and Liang, Man and Wang, Zhifang and Liu, Chunlong and Han, Yanlin},
title = {A candidate reference measurement procedure for quantification of glycocholic acid in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05449-9}
}
EUVIMED