The label-free electrochemical S100B-TBI immunosensor for sensitive detection of S100B protein as a biomarker for traumatic brain injury using FFT-SWV voltammetry
Clinica Chimica Acta · 2026-06 · 588 · 120964
DOI: 10.1016/j.cca.2026.120964 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2026-06. Verfasst von Mehrasa Rahimi Borumand und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Biomaterials and Medical Biomaterial Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran…. Hauptthemen laut MEDLINE: Brain Injuries, Traumatic, S100 Calcium Binding Protein beta Subunit, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Tehran University of Medical Sciences.
Abstract (Originalsprache)
S100B protein is an established biomarker related to prognosis in traumatic brain injury (TBI). Developing sensitive methods for the serum S100B quantification is clinically valuable. This paper proposes a simple label-free electrochemical TBI-immunosensor for the timely detection of S100B in the sera of TBI patients. In the first step of bioelectrode fabrication, gold nanoparticles-reduced graphene oxide (AuNPs-rGO) nanocomposite was layered onto a glassy carbon electrode (GCE) to improve the amplification of electrochemical signals. The anti-S100B was immobilized onto a modified-GCE via self-assembly monolayers using 11-Mercaptoundecanoic acid and EDC-NHS. Electrochemical immunoassay was planned based on forming of an immunocomplex bioaccumulation among S100B and anti-S100B, resulting in a decline peak current in the [Fe (CN)6]3-/4- redox couple. The modification steps of immobilization were morphologically or electrochemically characterized by scanning electron microscopy, cyclic voltammetry, and impedance spectroscopy techniques. A fast Fourier transform square wave voltammetry was applied to peak current change in accordance with the concentration of S100B under optimal experimental conditions. The fabricated immunosensor detected sensitively the S100B in the linear range of 0.75-75,000 pg mL-1, with a detection limit of 1.31 pg mL-1, which comprises the whole biosynthesis broad of S100B in healthy and TBI patients. Likewise, no cross-reactivity was observed with other interfering S100 family proteins, denoting the excellent selectivity and specificity. Moreover, good reproducibility and stability were obtained for the fabricated immunosensor. Immunosensor performance for S100B-spiked serum exhibited a recovery range of 93.33-106.64%. Given its analytical performance, this immunosensor shows promise as a tool for rapid serum S100B measurement in patients with TBI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmaceutical Biomaterials and Medical Biomaterial Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran.
- Department of Clinical Pharmacy, Faculty Of Pharmacy and Sina Hospital and Anesthesiology and Critical Care Medicine Research Center, Tehran University of Medical Sciences, Tehran, Iran.
- Drug Design and Development Research Center, The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran, Iran.
- Department of Horticulture Science, Biotechnology & Molecular Genetic Section, University of Hormozgan, Bandar Abbas, Iran.
- Anesthesia, Critical Care and Pain Management Research Center, Tehran University of Medical Sciences, Tehran, Iran.
- Department of Plant Pathology, Faculty of Agriculture, Tarbiat Modares University, Tehran, Iran.
Förderung
- Tehran University of Medical Sciences
Zitieren
APA
Borumand, M. R., Mojtahedzadeh, M., Hassani, S., Rad-Malekshahi, M., Kazemzadeh-Beneh, H., Kianpour, P., Babaloii, F., Karimzade, M., Mojtahedzadeh, A., Norouzi, P., & Javar, H. A. (2026). The label-free electrochemical S100B-TBI immunosensor for sensitive detection of S100B protein as a biomarker for traumatic brain injury using FFT-SWV voltammetry. Clinica Chimica Acta, 588, 120964. https://doi.org/10.1016/j.cca.2026.120964
Vancouver
Borumand MR, Mojtahedzadeh M, Hassani S, Rad-Malekshahi M, Kazemzadeh-Beneh H, Kianpour P, et al. The label-free electrochemical S100B-TBI immunosensor for sensitive detection of S100B protein as a biomarker for traumatic brain injury using FFT-SWV voltammetry. Clinica Chimica Acta. 2026;588:120964. doi:10.1016/j.cca.2026.120964
BibTeX
@article{Borumand2026,
author = {Borumand, Mehrasa Rahimi and Mojtahedzadeh, Mojtaba and Hassani, Shokoufeh and Rad-Malekshahi, Mazda and Kazemzadeh-Beneh, Hashem and Kianpour, Parisa and Babaloii, Fatemeh and Karimzade, Marziye and Mojtahedzadeh, Amirmahdi and Norouzi, Parviz and Javar, Hamid Akbari},
title = {The label-free electrochemical S100B-TBI immunosensor for sensitive detection of S100B protein as a biomarker for traumatic brain injury using FFT-SWV voltammetry},
journal = {Clinica Chimica Acta},
year = {2026},
volume = {588},
pages = {120964},
doi = {10.1016/j.cca.2026.120964}
}
EUVIMED