EUVIMEDEUVIMED entdecken
Crossref

Biogenic carbon dot-based fluorescence-mediated immunosensor for the detection of disease biomarker

Ankita Deb, Gaurav Raghunath Nalkar, Devasish Chowdhury

Analytica Chimica Acta · 2023-02 · 1242 · 340808

DOI: 10.1016/j.aca.2023.340808 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-02. Verfasst von Ankita Deb und 2 weiteren Autor:innen. Beteiligte Einrichtung: Material Nanochemistry Laboratory, Physical Sciences Division, Institute of Advanced Study in Science and Technology, Paschim Boragaon, Garchuk, Guwa…. Hauptthemen laut MEDLINE: Carbon, Biosensing Techniques. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The dynamic interplay of nanotechnology and immunoassay has unlocked an arena for developing next-generation techniques to contribute to detecting disease biomarkers. Herein, the work establishes the strategic fabrication of an immunosensor by sandwich technique based on the fluorescence phenomenon of carbon dots for the detection of the disease biomarker VEGF (Vascular Endothelial Growth Factor). VEGF, a biomarker for angiogenesis, is considered cancerous if found in elevated levels in the blood, and so is paramount for early detection of disease. Carbon dots derived from a biogenic source were synthesized employing a green microwave-assisted method followed by conjugating with a detection antibody, human immunoglobulin G (IgG), via EDC-NHS amidation reaction. On the other hand, the VEGF biomarker was immobilized onto the capture antibody. The detection antibody tagged with the fluorescent probe is employed as a bridge to connect with the VEGF biomarkers bound to the capture antibody. The response to different concentrations of VEGF biomarkers was recorded in terms of the fluorescence intensity of the carbon dots. The fluorescence immunosensor could exhibit a wide linear range of 0.1 fg/mL to 10 pg/mL with a low detection limit of 5.65 pg/mL towards VEGF. The potentiality of this designed immunosensor was qualitatively assessed with human blood plasma samples, showing promising results, thereby upholding the applicability of carbon dots as fluorescent labels in immunoassay techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarbonBiosensing TechniquesHumansVascular Endothelial Growth Factor AImmunoassayBiomarkersLimit of DetectionElectrochemical TechniquesGold

Stichwörter der Autor:innen

AntibodyBiomarkerBiosensorCarbon dotsFluorescenceImmunosensor

Substanzen

CarbonVascular Endothelial Growth Factor ABiomarkersGold

Autor:innen und Institutionen

  • Material Nanochemistry Laboratory, Physical Sciences Division, Institute of Advanced Study in Science and Technology, Paschim Boragaon, Garchuk, Guwahati, 781035, India.
  • Material Nanochemistry Laboratory, Physical Sciences Division, Institute of Advanced Study in Science and Technology, Paschim Boragaon, Garchuk, Guwahati, 781035, India. Electronic address: devasish@iasst.gov.in.

Zitieren

APA

Deb, A., Nalkar, G. R., & Chowdhury, D. (2023). Biogenic carbon dot-based fluorescence-mediated immunosensor for the detection of disease biomarker. Analytica Chimica Acta, 1242, 340808. https://doi.org/10.1016/j.aca.2023.340808

Vancouver

Deb A, Nalkar GR, Chowdhury D. Biogenic carbon dot-based fluorescence-mediated immunosensor for the detection of disease biomarker. Analytica Chimica Acta. 2023;1242:340808. doi:10.1016/j.aca.2023.340808

BibTeX
@article{Deb2023,
  author = {Deb, Ankita and Nalkar, Gaurav Raghunath and Chowdhury, Devasish},
  title = {Biogenic carbon dot-based fluorescence-mediated immunosensor for the detection of disease biomarker},
  journal = {Analytica Chimica Acta},
  year = {2023},
  volume = {1242},
  pages = {340808},
  doi = {10.1016/j.aca.2023.340808}
}
Kostenlos starten →