A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) – Teaching old dog new tricks
Clinica Chimica Acta · 2024
DOI: 10.1016/j.cca.2024.119877 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2024. Verfasst von Arkadiusz Kocur und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Faculty of Pharmacy, Medical University of Warsaw, 02-097 Warsaw, Poland; Thera…. Hauptthemen laut MEDLINE: Cyclosporine, Drug Monitoring, Kidney Transplantation, Tandem Mass Spectrometry. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND AND AIMS: Ciclosporin (CSA) is an immunosuppressive agent that requires therapeutic drug monitoring (TDM). High partitioning in erythrocytes indicates that whole blood (WB) is a suitable matrix for CSA determination. Alternative sampling strategies, such as volumetric absorptive microsampling (VAMS), are novel possibilities for blood collection during TDM for various analytes, including immunosuppressants. This technique is attractive for vulnerable pediatric patients, including home-based self-sampling, remote therapy, and adherence control. MATERIALS AND METHODS: This study aimed to develop and validate a new method for CSA determination based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) of WB and VAMS samples. Additionally, these methods were applied for CSA determination in clinical samples from pediatric transplant recipients. A strong point of this study is the assessment of an external proficiency testing scheme. RESULTS: Both methods were successfully validated within the 1-2000 ng/mL calibration range, with LOD 0.5 and 1 ng/mL for WB and VAMS methods, respectively. All the validation parameters fulfilled the international acceptance criteria for bioanalytical methods. Cross-validation confirmed the interchangeability of the LC-MS/MS method developed in this study. CONCLUSION: This study developed and validated novel methods for CSA determination in whole blood and VAMS using LC-MS/MS. Clinical validation and proficiency testing confirmed their utility in routine clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Faculty of Pharmacy, Medical University of Warsaw, 02-097 Warsaw, Poland; Therapeutic Drug Monitoring, Clinical Pharmacokinetics and Toxicology Labor…
- Student's Scientific Association in the Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Faculty of Pharmacy, Medical University of Warsaw, 02-097 Warsaw, Poland.
- Therapeutic Drug Monitoring, Clinical Pharmacokinetics and Toxicology Laboratory Unit, Department of Clinical Biochemistry, The Children's Memorial Health Institute, 04-730 Warsaw, Poland.
- Department of Nephrology, Kidney Transplantation and Arterial Hypertension, The Children's Memorial Health Institute, Dzieci Polskich 20, 04-730 Warsaw, Poland.
- Institute of Biological Sciences, Cardinal Stefan Wyszynski University, 1/3 Kazimierza Wóycickiego St, 01-938, Warsaw, Poland.
- Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Faculty of Pharmacy, Medical University of Warsaw, 02-097 Warsaw, Poland.
Zitieren
APA
Kocur, A., Kot, B., Moczulski, M., Czajkowska, A., Rubik, J., Sierakowski, M., & Pawiński, T. (2024). A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) – Teaching old dog new tricks. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.119877
Vancouver
Kocur A, Kot B, Moczulski M, Czajkowska A, Rubik J, Sierakowski M, et al. A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) – Teaching old dog new tricks. Clinica Chimica Acta. 2024. doi:10.1016/j.cca.2024.119877
BibTeX
@article{Kocur2024,
author = {Kocur, Arkadiusz and Kot, Bartłomiej and Moczulski, Mateusz and Czajkowska, Agnieszka and Rubik, Jacek and Sierakowski, Maciej and Pawiński, Tomasz},
title = {A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) – Teaching old dog new tricks},
journal = {Clinica Chimica Acta},
year = {2024},
doi = {10.1016/j.cca.2024.119877}
}