EUVIMEDEUVIMED entdecken
LeserbriefOpen Access · CC BY 4.0

Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials

Tulika Nandi, Ainslie Johnstone, Eleanor Martin, Catharina Zich, Robert Cooper, Sven Bestmann, Til Ole Bergmann, Bradley Treeby, Charlotte J Stagg

Brain Stimulation · 2023

DOI: 10.1016/j.brs.2023.02.004 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Brain Stimulation, 2023. Verfasst von Tulika Nandi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, UK; Neuroimaging Cen…. Hauptthemen laut MEDLINE: Visual Cortex, Ultrasonic Therapy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Department of Health, Boehringer Ingelheim Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcranial ultrasonic stimulation (TUS), has been shown to evoke ‘visual evoked potential (VEP)-like’ potentials on EEG recordings, and also to modulate sensory evoked potentials. However, pulsed TUS is accompanied by an auditory confound, and it is possible that any observed effects were, in-part, evoked by this confound. Therefore, we used ramped TUS pulses, which are not as easily audible, to examine whether primary visual cortex (V1) TUS evokes VEP-like potentials, and modulates VEPs elicited using a checkerboard stimulus. Methods We tested 14 healthy participants (31 ± 4.3 yrs, 4 F and 10 M). TUS was applied to the left V1 using a 270 kHz transducer (H115-2AA, Sonic Concepts). Ramped pulses (1 ms ramp, 3.25 ms total pulse duration) were repeated at 250 Hz, with a pulse train duration of 300 ms, an effective duty cycle of 50%, and Isppa without ramping of 16 W/cm 2 in water. EEG was recorded from 16 channels using the g.USBamp amplifier (g.tec medical engineering GmbH). In two blocks (TUS-only), real and sham (100 each) TUS trials were repeated every 2 s. In another two blocks (TUS+checkerboard), a checkerboard stimulus was flipped every 0.5 s, and every fourth stimulus was associated with either a real or sham (100 each) TUS trial. The TUS trial started approx. 130 ms (0-5 ms jitter) before the checkerboard flip. All EEG data were analysed using Fieldtrip, and cluster-based permutation tests were used to test for differences between conditions. Results and discussion In the TUS-only condition, in contrast to a previous study, we found no evoked potentials using ramped pulses which minimised the auditory artifact. In the TUS+checkerboard condition, we observed a modulation of the early-component of the VEP in real TUS, relative to no TUS trials. This suggests that, in line with in-vitro and animal data, there is a direct neuromodulatory effect of ultrasound, in addition to any confounding effects. Moving forward, ramping offers a relatively easy approach to minimise the auditory confound.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual CortexUltrasonic TherapyEvoked Potentials, VisualTranscranial Magnetic StimulationEvoked PotentialsEvoked Potentials, Motor

Autor:innen und Institutionen

  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, UK; Neuroimaging Center (NIC), Johannes Gutenberg University Medical Center, Mainz, German…
  • Department for Clinical and Movement Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK.
  • Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Wellcome/EPSRC Centre for Interventional & Surgical Sciences, University College London, London, UK.
  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, UK; Department for Clinical and Movement Neuroscience, UCL Queen Square Institute of Neuro…
  • Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
  • Department for Clinical and Movement Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, Univers…

Förderung

  • Wellcome Trust
  • Department of Health
  • Boehringer Ingelheim Stiftung
  • Brain Research UK
  • NIHR Oxford Biomedical Research Centre
  • UK Research and Innovation
  • Wellcome / EPSRC Centre for Interventional and Surgical Sciences
  • Engineering and Physical Sciences Research Council

Zitieren

APA

Nandi, T., Johnstone, A., Martin, E., Zich, C., Cooper, R., Bestmann, S., Bergmann, T. O., Treeby, B., & Stagg, C. J. (2023). Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials. Brain Stimulation. https://doi.org/10.1016/j.brs.2023.02.004

Vancouver

Nandi T, Johnstone A, Martin E, Zich C, Cooper R, Bestmann S, et al. Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials. Brain Stimulation. 2023. doi:10.1016/j.brs.2023.02.004

BibTeX
@article{Nandi2023,
  author = {Nandi, Tulika and Johnstone, Ainslie and Martin, Eleanor and Zich, Catharina and Cooper, Robert and Bestmann, Sven and Bergmann, Til Ole and Treeby, Bradley and Stagg, Charlotte J},
  title = {Ramped V1 transcranial ultrasonic stimulation modulates but does not evoke visual evoked potentials},
  journal = {Brain Stimulation},
  year = {2023},
  doi = {10.1016/j.brs.2023.02.004}
}
Kostenlos starten →