Assessing SICI Cortical Inhibition With DLPFC TMS‐EEG Using Different ISI Values
Psychophysiology · 2026
DOI: 10.1111/psyp.70229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Psychophysiology, 2026. Verfasst von Gema Mijancos-Martínez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Automatic Control Department (ESAII) and Institute for Research and Innovation in Health (IRIS), Universitat Politècnica de Catalunya - BarcelonaTech…. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Electroencephalography, Neural Inhibition, Dorsolateral Prefrontal Cortex. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: MCIN/AEI/10.13039/501100011033, Agència de Gestió d'Ajuts Universitaris i de Recerca, HybridNeuro.
Abstract (Originalsprache)
The evaluation of cortical inhibition (CI) in dorsolateral prefrontal cortex (DLPFC) using transcranial magnetic stimulation combined with electroencephalography (TMS‐EEG) has focused great attention in recent years. One of the most common procedures to assess such inhibition is the short‐interval cortical inhibition (SICI), a paired‐pulse paradigm defined by the interstimulus interval (ISI). While SICI was initially defined and extensively used in studies targeting the motor cortex, its application to the DLPFC is relatively recent. However, little is known about how ISI values affect the DLFPC, especially in terms of the TMS‐evoked potentials (TEP). This study aims to quantitatively compare the effects of different ISI values in the SICI protocol on CI in the DLPFC by assessing TEPs. Eighteen healthy subjects underwent the SICI protocol using two different ISIs: 2 ms and 4 ms. TMS‐EEG responses for both ISIs were characterized in terms of amplitude, latency, peak‐to‐peak amplitudes, and the area under the rectified curve of the TEPs. The results indicate that TEPs differed depending on the ISI used, finding a significantly greater inhibition with 2 ms ISI, as reflected by a more pronounced reduction in TEP amplitude. These findings are consistent with previous literature on motor cortex stimulation, suggesting that a greater reduction in TEP, and hence greater inhibition, is likely achieved with a 2 ms ISI. Therefore, the study helps in the standardization of SICI protocol in DLFPC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Automatic Control Department (ESAII) and Institute for Research and Innovation in Health (IRIS), Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Barcelona, Spain.
- Institute of Research Sant Joan de Déu, Barcelona, Spain.
- Psychiatry Department, School of Medicine, University of Valladolid, Valladolid, Spain.
- CIBER of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain.
- Psychiatry Service, Clinical Hospital of Valladolid, Valladolid, Spain.
- Neurosciences Institute of Castilla y Léon (INCYL), University of Salamanca, Salamanca, Spain.
ORCID-Profile: Gema Mijancos-Martínez
Förderung
- MCIN/AEI/10.13039/501100011033
- Agència de Gestió d'Ajuts Universitaris i de Recerca
- HybridNeuro
- Instituto de Salud Carlos III
- Gerencia Regional de Salud de Castilla y León
- Fundació la Marató de TV3
- MICIU/AEI/10.13039/501100011033
Zitieren
APA
Mijancos-Martínez, G., Bachiller, A., Fernández-Linsenbarth, I., Ruiz-Gómez, S. J., Romero, S., Molina, V., & Mañanas, M. Á. (2026). Assessing SICI Cortical Inhibition With DLPFC TMS‐EEG Using Different ISI Values. Psychophysiology. https://doi.org/10.1111/psyp.70229
Vancouver
Mijancos-Martínez G, Bachiller A, Fernández-Linsenbarth I, Ruiz-Gómez SJ, Romero S, Molina V, et al. Assessing SICI Cortical Inhibition With DLPFC TMS‐EEG Using Different ISI Values. Psychophysiology. 2026. doi:10.1111/psyp.70229
BibTeX
@article{MijancosMartnez2026,
author = {Mijancos-Martínez, Gema and Bachiller, Alejandro and Fernández-Linsenbarth, Inés and Ruiz-Gómez, Saúl J and Romero, Sergio and Molina, Vicente and Mañanas, Miguel Ángel},
title = {Assessing SICI Cortical Inhibition With DLPFC TMS‐EEG Using Different ISI Values},
journal = {Psychophysiology},
year = {2026},
doi = {10.1111/psyp.70229}
}