EUVIMEDEUVIMED entdecken
Crossref

A novel dose-based intra-preplan method for high-dose-rate brachytherapy in cervical cancer using modeling and optimization algorithms

Shinya Komori, Yoshiaki Takagawa, Hiroki Sato, Masanori Machida, Masato Kato, Hisao Ouchi, Hiromitsu Endo, Wataru Itano, Takahiro Kato

Brachytherapy · 2025

DOI: 10.1016/j.brachy.2025.07.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2025. Verfasst von Shinya Komori und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics and Technology, Southern Tohoku General Hospital, Koriyama, Fukushima, Japan; Department of Radiation Physics and Tec…. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy Planning, Computer-Assisted, Algorithms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Elekta.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study presents the dose-based intra-preplan (DIP) method for intracavitary/interstitial brachytherapy (IC/ISBT) in cervical cancer, optimizing catheter configurations based on dose distribution. This study aimed to assess the DIP method's clinical feasibility and efficacy. METHODS AND MATERIALS: The DIP method incorporates the implant modeling function and the hybrid inverse planning optimization algorithm in Oncentra Brachy. Virtual applicator and catheter models were created and merged with patient-specific computed tomography images. Subsequently, an optimization algorithm was used to automatically determine the optimal catheter configuration-including the number, positions, and insertion depths. The workflow was retrospectively validated in 14 IC/ISBT patients treated with the Geneva applicators. Catheter configurations from the DIP and conventional intra-preplan (IP) methods were compared in terms of catheter number and dose-volume histogram (DVH) parameters for high-risk clinical target volume (CTVHR) and organs at risk (OARs). To evaluate the optimality of the DIP-based configurations, DVH parameters were assessed after changing the number of catheters. RESULTS: The DIP workflow was successfully established. Compared to the IP method, the DIP method achieved similar DVH parameters for both CTVHR and OARs with significantly fewer catheters (p < 0.01). The addition of catheters did not significantly alter DVH parameters, while their reduction significantly compromised CTVHR coverage (p < 0.01) and increased OAR doses (p < 0.05). CONCLUSIONS: The DIP method enables patient-specific optimization of minimal catheter configurations and supports the broader implementation of high-quality IC/ISBT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyUterine Cervical NeoplasmsRadiotherapy Planning, Computer-AssistedAlgorithmsHumansFemaleRadiotherapy DosageRetrospective StudiesOrgans at RiskTomography, X-Ray Computed

Stichwörter der Autor:innen

Cervical cancerGeneva applicatorHigh-dose-rate brachytherapyHybrid applicatorHybrid brachytherapy

Autor:innen und Institutionen

  • Department of Radiation Physics and Technology, Southern Tohoku General Hospital, Koriyama, Fukushima, Japan; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, Koriyama, Fukushima, Ja…
  • Department of Radiation Oncology, Southern Tohoku General Hospital, Koriyama, Fukushima, Japan; Department of Minimally Invasive Surgical and Medical Oncology, Fukushima Medical University, Fukushima, Fukushima, Japan.
  • Department of Radiation Physics and Technology, Southern Tohoku General Hospital, Koriyama, Fukushima, Japan.
  • Department of Radiation Oncology, Southern Tohoku General Hospital, Koriyama, Fukushima, Japan.
  • Chiyoda Technol Corporation, Bunkyo-ku, Tokyo, Japan.
  • Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima, 960-8516, Japan.

Förderung

  • Elekta

Zitieren

APA

Komori, S., Takagawa, Y., Sato, H., Machida, M., Kato, M., Ouchi, H., Endo, H., Itano, W., & Kato, T. (2025). A novel dose-based intra-preplan method for high-dose-rate brachytherapy in cervical cancer using modeling and optimization algorithms. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.07.007

Vancouver

Komori S, Takagawa Y, Sato H, Machida M, Kato M, Ouchi H, et al. A novel dose-based intra-preplan method for high-dose-rate brachytherapy in cervical cancer using modeling and optimization algorithms. Brachytherapy. 2025. doi:10.1016/j.brachy.2025.07.007

BibTeX
@article{Komori2025,
  author = {Komori, Shinya and Takagawa, Yoshiaki and Sato, Hiroki and Machida, Masanori and Kato, Masato and Ouchi, Hisao and Endo, Hiromitsu and Itano, Wataru and Kato, Takahiro},
  title = {A novel dose-based intra-preplan method for high-dose-rate brachytherapy in cervical cancer using modeling and optimization algorithms},
  journal = {Brachytherapy},
  year = {2025},
  doi = {10.1016/j.brachy.2025.07.007}
}
Kostenlos starten →