EUVIMEDEUVIMED entdecken
Systematische ÜbersichtÜbersichtsarbeit

Applicator reconstruction in cervical cancer brachytherapy: A systematic review of current methods, challenges, and AI-driven future directions

Vida Sargazi, Shahrokh Naseri, Hamid Gholamhosseinian, Mehdi Momennezhad

Brachytherapy · 2026

DOI: 10.1016/j.brachy.2025.10.004 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Brachytherapy, 2026. Verfasst von Vida Sargazi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Radiology, Faculty of Parame…. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy, Image-Guided, Artificial Intelligence. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Accurate applicator reconstruction is a critical step in 3D image-guided brachytherapy (3D-IGBT) for cervical cancer, directly influencing tumor control and organ-at-risk sparing. This systematic review evaluates the accuracy, efficiency, and clinical impact of applicator reconstruction methods, focusing on AI's potential to overcome existing limitations. METHODS AND MATERIALS: Following PRISMA guidelines, 23 studies from MEDLINE, PubMed, Scopus, Embase, Lilacs and Web of Science (up to May 2025) were analyzed. Evaluation metrics included geometric accuracy (tip error, Hausdorff distance), reconstruction time, and dosimetric parameters (D90 HR-CTV, D2cc OARs). Methods assessed spanned manual (e.g., MPR, scout-based), semi-automatic (library method, clustering algorithms), and AI-driven approaches (e.g., U-Net, Dilated-Supervised Deep U-Net, Attention-Gated networks). Special focus was placed on deep learning (DL) architectures and their ability to overcome metallic artifacts, partial-volume effects, and inter-operator variability. RESULTS: Manual methods exhibited significant limitations, with tip errors reaching 4.1 mm. Semi-automated approaches reduced variability (library-based methods: 0.89) and dosimetric consistency (D2cc deviations

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyUterine Cervical NeoplasmsRadiotherapy, Image-GuidedArtificial IntelligenceHumansFemaleImaging, Three-DimensionalRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

Applicator reconstructionBrachytherapyDeep learningDosimetric ImpactGeometric accuracycervix cancer

Autor:innen und Institutionen

  • Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Radiology, Faculty of Paramedicine, Zahedan University of Medical Sciences, Zahedan, Iran.
  • Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Medical Physics Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. Electronic address: Mom…

Zitieren

APA

Sargazi, V., Naseri, S., Gholamhosseinian, H., & Momennezhad, M. (2026). Applicator reconstruction in cervical cancer brachytherapy: A systematic review of current methods, challenges, and AI-driven future directions. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.10.004

Vancouver

Sargazi V, Naseri S, Gholamhosseinian H, Momennezhad M. Applicator reconstruction in cervical cancer brachytherapy: A systematic review of current methods, challenges, and AI-driven future directions. Brachytherapy. 2026. doi:10.1016/j.brachy.2025.10.004

BibTeX
@article{Sargazi2026,
  author = {Sargazi, Vida and Naseri, Shahrokh and Gholamhosseinian, Hamid and Momennezhad, Mehdi},
  title = {Applicator reconstruction in cervical cancer brachytherapy: A systematic review of current methods, challenges, and AI-driven future directions},
  journal = {Brachytherapy},
  year = {2026},
  doi = {10.1016/j.brachy.2025.10.004}
}
Kostenlos starten →