Development of a phantom and analysis of brachytherapy dosimetry using the sulfamic acid/electron paramagnetic resonance system
Brachytherapy · 2026
DOI: 10.1016/j.brachy.2025.10.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2026. Verfasst von Ghizlane Boukhris und 6 weiteren Autor:innen. Beteiligte Einrichtung: Watch Laboratory for Emerging Technologies, Faculty of Science and Techniques, University Hassan I, Settat, Morocco. Electronic address: g.boukhris@u…. Hauptthemen laut MEDLINE: Brachytherapy, Phantoms, Imaging, Radiometry, Sulfonic Acids. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Design and develop an epoxy resin-based cylindrical phantom to simulate cancer treatment conditions in high dose rate (HDR) brachytherapy and evaluate the spatial dose distribution around a 192Ir source using an Sulfamic Acid/EPR system. METHODS AND MATERIALS: A cylindrical phantom was fabricated from epoxy resin, allowing the precise insertion of a 192Ir HDR brachytherapy source and multiple sulfamic acid dosimeters at predefined positions. The dosimetric system used in this study combined sulfamic acid detectors with EPR readout to quantify absorbed doses. Dosimeters were irradiated with doses ranging from 1 to 8 Gy, and the EPR signal intensities were measured to construct a calibration curve. Several dosimeters were then strategically positioned at various distances from the source to experimentally determine the dose distribution within the phantom. RESULTS: The EPR dosimetry system showed a linear dose-response relationship within the 1-8 Gy range. The absorbed dose values at different locations were derived from the established calibration curve. A steep dose gradient was observed near the 192Ir source, in agreement with theoretical expectations for HDR brachytherapy. The overall uncertainty in the dose evaluation process was estimated to be approximately 8% (k = 2). CONCLUSIONS: This study demonstrates that the EPR/sulfamic acid dosimetry system provides a reliable and accurate method for dose evaluation in HDR brachytherapy. The developed epoxy resin phantom offers a practical and reproducible platform for experimental dose verification and quality assurance in brachytherapy treatments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Watch Laboratory for Emerging Technologies, Faculty of Science and Techniques, University Hassan I, Settat, Morocco. Electronic address: g.boukhris@uhp.ac.ma.
- Watch Laboratory for Emerging Technologies, Faculty of Science and Techniques, University Hassan I, Settat, Morocco.
- Laboratory of Health Sciences and Technologies, High Institute of Health Sciences, University Hassan I, Settat, Morocco.
- Ryad Oncologia Clinic, Casablanca, Morocco.
Zitieren
APA
Boukhris, G., Mikou, M., El Rhazouani, O., El Baydaoui, R., Jebbari, S., Bouk, A., & Kamal, D. (2026). Development of a phantom and analysis of brachytherapy dosimetry using the sulfamic acid/electron paramagnetic resonance system. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.10.002
Vancouver
Boukhris G, Mikou M, El Rhazouani O, El Baydaoui R, Jebbari S, Bouk A, et al. Development of a phantom and analysis of brachytherapy dosimetry using the sulfamic acid/electron paramagnetic resonance system. Brachytherapy. 2026. doi:10.1016/j.brachy.2025.10.002
BibTeX
@article{Boukhris2026,
author = {Boukhris, Ghizlane and Mikou, Mohammed and El Rhazouani, Omar and El Baydaoui, Redouane and Jebbari, Sofia and Bouk, Abdeslam and Kamal, Dounia},
title = {Development of a phantom and analysis of brachytherapy dosimetry using the sulfamic acid/electron paramagnetic resonance system},
journal = {Brachytherapy},
year = {2026},
doi = {10.1016/j.brachy.2025.10.002}
}
EUVIMED