Integrated optimization of needle paths and dwell time for individualized template‐guided interstitial brachytherapy

Qinglong Yao, Kaiyue Wang, Bo Liu, Ping Jiang, Fugen Zhou, Junjie Wang, Qiuwen Wu

Medical Physics · 2026

DOI: 10.1002/mp.70411 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Qinglong Yao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Image Processing Center, Beihang University, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Brachytherapy, Needles, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 71 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Key Specialty program of Natural Science Foundation, National Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

3D‐printed individualized template (3D‐PIT) guided interstitial brachytherapy (ISBT) is an effective treatment modality for cervical cancer. However, the current practice of pre‐operative planning requires manual needle paths design, which is highly dependent on operator experience and may lead to unnecessary insertion trauma.

Purpose

To address this issue, this study introduces and validates an automated integrated optimization method for needle paths and dwell times for an institutional protocol of 3D‐PIT based ISBT for locally recurrent cervical cancer. Methods and Materials To automatically generate a treatment plan, a candidate needle path set was first generated based on patient's anatomy and the transvaginal template. Then, a two‐layer optimization strategy was introduced for automated integrated optimization of the needle paths and dwell times, with the outer layer employing simulated annealing to optimize the needle paths, and the inner layer to optimize the dwell times. A total of 40 patient cases (with the prescribed dose to HR‐CTV D 90% being 6 Gy (physical dose) per fraction, and 2–8 fractions per case, totaling 219 independent fraction plans) with locally recurrent cervical cancer previously treated with 3D‐PIT‐assisted ISBT were enrolled in this study. Automatic plans for all fractions were generated and evaluated using the same number of needles as in the clinical plans, with the dosimetric results of the clinical plans used as constraints. In addition, the quality of automatic plans using fewer needles was also investigated.

Results

The method generated clinically acceptable plans in 1.5 ± 1.2 min, requiring 145 ± 74 iterations, according to institutional protocols based on the EMBRACE II. In terms of dosimetric quality, the automatic plans met the constraints and generally outperformed the clinical plans in protecting organs‐at‐risk (OARs). When normalizing both plans to the same HR‐CTV D 90% and comparing the dosimetric outcomes of OARs, the D 2cc of rectum, bladder, colon, and small intestine were reduced from 363 to 350 cGy, 397 to 376 cGy, 226 to 204 cGy, and 140 to 123 cGy, respectively (all p < 0.001). The D 0.1cc of urethra was reduced from 406 to 351 cGy ( p < 0.001). V 100% of HR‐CTV remained the same at 78% ( p = 0.28), and V 150% of HR‐CTV was increased from 42% to 44% ( p < 0.001). Total dwell time decreased from 278 to 271 seconds ( p < 0.001). In addition, plans with fewer needles generally had higher doses to OARs.

Conclusions

The automated integrated optimization method provides a fast, standardized pre‐planning tool for 3D‐PIT‐assisted ISBT. By reducing operator dependence, it serves as a valuable clinical baseline to help determine optimal needle configurations and maintain consistent dosimetric quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyNeedlesRadiotherapy, Image-GuidedHumansRadiotherapy Planning, Computer-AssistedTime FactorsFemalePrinting, Three-DimensionalUterine Cervical NeoplasmsRadiotherapy Dosage

Stichwörter der Autor:innen

3D‐printed individualized templatecervical cancerinterstitial brachytherapysimulated annealing optimizationtreatment planning

Autor:innen und Institutionen

  • Image Processing Center, Beihang University, Beijing, People's Republic of China.
  • Department of Radiation Oncology, Peking University Third Hospital, Beijing, People's Republic of China.
  • Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA.

Förderung

  • Beijing Natural Science Foundation
  • Key Specialty program of Natural Science Foundation
  • National Natural Science Foundation
  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Yao, Q., Wang, K., Liu, B., Jiang, P., Zhou, F., Wang, J., & Wu, Q. (2026). Integrated optimization of needle paths and dwell time for individualized template‐guided interstitial brachytherapy. Medical Physics. https://doi.org/10.1002/mp.70411

Vancouver

Yao Q, Wang K, Liu B, Jiang P, Zhou F, Wang J, et al. Integrated optimization of needle paths and dwell time for individualized template‐guided interstitial brachytherapy. Medical Physics. 2026. doi:10.1002/mp.70411

BibTeX
@article{Yao2026,
  author = {Yao, Qinglong and Wang, Kaiyue and Liu, Bo and Jiang, Ping and Zhou, Fugen and Wang, Junjie and Wu, Qiuwen},
  title = {Integrated optimization of needle paths and dwell time for individualized template‐guided interstitial brachytherapy},
  journal = {Medical Physics},
  year = {2026},
  doi = {10.1002/mp.70411}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche