EUVIMEDEUVIMED entdecken
Open Access

Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy

Tonghe Wang, Yining Feng, Joel Beaudry, David Aramburu Nunez, Daniel Gorovets, Marisa Kollmeier, Antonio L Damato

Brachytherapy · 2025

DOI: 10.1016/j.brachy.2024.10.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2025. Verfasst von Tonghe Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065. Electronic address: wangt8@mskcc.org. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Brachytherapy, Radiotherapy Planning, Computer-Assisted, Ultrasonography, Interventional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health, National Cancer Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We investigated the feasibility of AI to provide an instant feedback of the potential plan quality based on live needle placement, and before planning is initiated. MATERIALS AND METHODS: We utilized YOLOv8 to perform automatic organ segmentation and needle detection on 2D transrectal ultrasound images. The segmentation and detection results for each patient were then fed into a plan quality prediction model based on ResNet101. Its outputs are values of selected dose volume metrics. Imaging and plan data from 504 prostate HDR boost patients (456 for training, 24 for validation, and 24 for testing) treated in our clinic were included in this study. The segmentation, needle detection, and prediction results were compared to the clinical results (ground truth). RESULTS: For prediction model, the p-values of t-test between the predicted values and ground truth for either rectum D2cc or urethra D20% were larger than 0.8. The sensitivity of prediction model in finding implant geometries resulting in below-median rectum D2cc and urethra D20% were 83% and 87%. CONCLUSION: The proposed method has great potential to facilitate the current prostate HDR brachytherapy workflows by providing valuable feedback during needle insertion, and facilitating decision making of where and if additional needles are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsBrachytherapyRadiotherapy Planning, Computer-AssistedUltrasonography, InterventionalHumansMaleRadiotherapy DosageUltrasonographyRectumFeasibility Studies

Autor:innen und Institutionen

  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065. Electronic address: wangt8@mskcc.org.
  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065.

Förderung

  • NCI NIH HHS
  • National Institutes of Health
  • National Cancer Institute

Zitieren

APA

Wang, T., Feng, Y., Beaudry, J., Aramburu Nunez, D., Gorovets, D., Kollmeier, M., & Damato, A. L. (2025). Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2024.10.009

Vancouver

Wang T, Feng Y, Beaudry J, Aramburu Nunez D, Gorovets D, Kollmeier M, et al. Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy. Brachytherapy. 2025. doi:10.1016/j.brachy.2024.10.009

BibTeX
@article{Wang2025,
  author = {Wang, Tonghe and Feng, Yining and Beaudry, Joel and Aramburu Nunez, David and Gorovets, Daniel and Kollmeier, Marisa and Damato, Antonio L},
  title = {Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy},
  journal = {Brachytherapy},
  year = {2025},
  doi = {10.1016/j.brachy.2024.10.009}
}
Kostenlos starten →