A single-centre, randomised comparison of the performance and safety of a novel mechanomyography sensor with electromyography
British Journal of Anaesthesia · 2026
DOI: 10.1016/j.bja.2025.10.067 ↗Kurz gefasst
Äquivalenzstudie in der Zeitschrift British Journal of Anaesthesia, 2026. Verfasst von Anna S Scholze und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Myography, Neuromuscular Monitoring. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: mechanosensor; MIPM, Mammendorf, Germany) compared with electromyography. METHODS: i.v. The primary endpoint was precision using the repeatability coefficient at baseline and full recovery. Precision of the TOF ratio measurement was assumed noninferior if the repeatability coefficient did not exceed a margin of 0.01. RESULTS: Mechanomyography had higher repeatability coefficients than electromyography at all measured TOF intervals. Mechanomyography was partially noninferior to electromyography because the 95% confidence interval of the median difference between TOF ratios of both techniques (0.039 [0.007 to 0.042]) covered the acceptable margin during baseline, but not after recovery to TOF ratio >0.9 (0.052 [0.047 to 0.076]). CONCLUSIONS: mechanosensor was not less precise than electromyography during baseline. Better hand fixation must be achieved to improve precision mechanomyography. CLINICAL TRIAL REGISTRATION: EUDAMED (CIV-23-06-043334); ClinicalTrials.gov (NCT06230653).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
- Department of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany; Department of Anaesthesiology and Intensive Care Medicine, Faculty of Medici…
- Department of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of Ulm, Ulm, Germany.
- Department of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of Ulm, Ulm, Germany; Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Clinical Division of General Anaesth…
Zitieren
APA
Scholze, A. S., Ulm, B., Kretsch, N., Jungwirth, B., Blobner, M., & Scheffenbichler, F. T. (2026). A single-centre, randomised comparison of the performance and safety of a novel mechanomyography sensor with electromyography. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2025.10.067
Vancouver
Scholze AS, Ulm B, Kretsch N, Jungwirth B, Blobner M, Scheffenbichler FT. A single-centre, randomised comparison of the performance and safety of a novel mechanomyography sensor with electromyography. British Journal of Anaesthesia. 2026. doi:10.1016/j.bja.2025.10.067
BibTeX
@article{Scholze2026,
author = {Scholze, Anna S and Ulm, Bernhard and Kretsch, Nadine and Jungwirth, Bettina and Blobner, Manfred and Scheffenbichler, Flora T},
title = {A single-centre, randomised comparison of the performance and safety of a novel mechanomyography sensor with electromyography},
journal = {British Journal of Anaesthesia},
year = {2026},
doi = {10.1016/j.bja.2025.10.067}
}
EUVIMED