Integrated Iontronic FMG‐sEMG Sensing for Decoding Muscle Activation Mechanisms and Force Assessment
Advanced Healthcare Materials · 2025
DOI: 10.1002/adhm.202500843 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Peikai Zou und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engi…. Hauptthemen laut MEDLINE: Electromyography, Muscle, Skeletal, Myography. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Development and Reform Commission,National Key R&D Program of China, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Muscle activity generates both physiological electrical and mechanical signals, the monitoring of which is crucial in rehabilitation and sports medicine, underpinning effective diagnosis, treatment, and rehabilitation processes. Advances in flexible electronics enable force myography (FMG) and surface electromyography (sEMG) signals for muscle activation monitoring, but the multi‐sensor integration and physiological mechanisms underlying FMG signals remain poorly studied, limiting the accuracy of muscle function assessments and underutilizes the high sensitivity of the flexible sensors. This study introduces a novel thin‐film iontronic force‐electromyography (iFEMG) sensor, integrating a high‐sensitivity iontronic pressure sensor and sEMG electrodes for high‐fidelity muscle physiological signal acquisition. Based on ultrasound imaging and statistical analysis, the relationship between muscle force, muscle geometric features, and FMG signals is established, providing evidence for elucidating the physiological mechanisms of FMG signals. Based on these findings, an effective and highly adaptable method is proposed for precise muscle force prediction. The iFEMG system is successfully applied to assess motor nerve and muscle function in patients, demonstrating its clinical utility. This system holds significant potential for broader applications, such as rehabilitation training and early diagnosis of musculoskeletal disorders, paving the way for advanced personalized healthcare solutions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang…
- Peking University Fourth School of Clinical Medicine, Xi Cheng District, Beijing, 100035, China.
- Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 100035, China.
- School of Engineering Medicine, Beihang University, Beijing, 100083, China.
ORCID-Profile: Peikai Zou, Ruya Li
Förderung
- National Development and Reform Commission,National Key R&D Program of China
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- Beijing Jishuitan Hospital
- National Center for Orthopaedics
- Capital Medical University
Zitieren
APA
Zou, P., Wang, J., Zhao, X., Zhang, X., Hua, K., Zha, Y., Li, R., & Fan, Y. (2025). Integrated Iontronic FMG‐sEMG Sensing for Decoding Muscle Activation Mechanisms and Force Assessment. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202500843
Vancouver
Zou P, Wang J, Zhao X, Zhang X, Hua K, Zha Y, et al. Integrated Iontronic FMG‐sEMG Sensing for Decoding Muscle Activation Mechanisms and Force Assessment. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202500843
BibTeX
@article{Zou2025,
author = {Zou, Peikai and Wang, Junhan and Zhao, Xian and Zhang, Xigong and Hua, Kehan and Zha, Yejun and Li, Ruya and Fan, Yubo},
title = {Integrated Iontronic FMG‐sEMG Sensing for Decoding Muscle Activation Mechanisms and Force Assessment},
journal = {Advanced Healthcare Materials},
year = {2025},
doi = {10.1002/adhm.202500843}
}
EUVIMED