EUVIMEDEUVIMED entdecken
Crossref

One-year evaluation of a 128-channel flexible IrOx neural interface and development of a miniaturized 256-channel integrated prototype

Dongyang Wen, Longchun Wang, Guijun Shu, Yang Xiao, Linkun Gu, Xiao Wang, Ming Yin, Jingquan Liu

Biosensors and Bioelectronics · 2027-02 · 318 · 119389

DOI: 10.1016/j.bios.2026.119389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Dongyang Wen und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; School of Integrat…. Die Arbeit nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-density neural interfaces require both durable electrode-tissue interfaces and compact electronic integration. Here, we combine a year-long evaluation of a 128-channel flexible IrOx electrode array (128-Flex) with the development of a miniaturized 256-channel integrated prototype (256-prot). IrOx modification reduced the mean 1 kHz impedance from 1.096 MΩ to 18.15 kΩ and increased charge storage capacity from 2.02 to 15.37 mC/cm2. Periodic in vivo recordings extended to 12 and 7 months in two rabbits, respectively, with final-session mean SNR values of 6.18 and 5.88 among spike-detecting channels. Post-explantation characterization of the 12-month device showed retained electrode morphology and electrochemical functionality, with a mean impedance of 48.60 kΩ and charge storage capacity of 8.67 mC/cm2. Building on this electrode platform, two 128-channel ASIC modules were integrated through a resin-based feedthrough substrate and two BGA interfaces into a 13 × 13 × 3 mm bare module weighing 1.03 g. The prototype recorded LFPs and spike activity at 1.5 months in an independent rabbit, with 80 and 73 effective recording channels in separately acquired module datasets. Enclosure optimization remains a priority for extending integrated-system evaluation. These results support the long-term recording utility of the flexible IrOx interface and the feasibility of the compact integration strategy.

Schlagwörter

Stichwörter der Autor:innen

Chronic neural recordingFlexible brain-machine interfaceHeterogeneous integrationHigh-density prototypeIridium oxide (IrO(x))Miniaturized bioelectronics

Autor:innen und Institutionen

  • National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; School of Integrated Circuits (School of Information Science and Electronic Engineering)…
  • National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • State Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou, 570100, China.
  • National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China. Electronic address: jqliu@sjtu.edu.cn.

Zitieren

APA

Wen, D., Wang, L., Shu, G., Xiao, Y., Gu, L., Wang, X., Yin, M., & Liu, J. (2027). One-year evaluation of a 128-channel flexible IrOx neural interface and development of a miniaturized 256-channel integrated prototype. Biosensors and Bioelectronics, 318, 119389. https://doi.org/10.1016/j.bios.2026.119389

Vancouver

Wen D, Wang L, Shu G, Xiao Y, Gu L, Wang X, et al. One-year evaluation of a 128-channel flexible IrOx neural interface and development of a miniaturized 256-channel integrated prototype. Biosensors and Bioelectronics. 2027;318:119389. doi:10.1016/j.bios.2026.119389

BibTeX
@article{Wen2027,
  author = {Wen, Dongyang and Wang, Longchun and Shu, Guijun and Xiao, Yang and Gu, Linkun and Wang, Xiao and Yin, Ming and Liu, Jingquan},
  title = {One-year evaluation of a 128-channel flexible IrOx neural interface and development of a miniaturized 256-channel integrated prototype},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {318},
  pages = {119389},
  doi = {10.1016/j.bios.2026.119389}
}
Kostenlos starten →