Flexible IrOx neural electrode for mouse vagus nerve stimulation
Acta Biomaterialia · 2023-03 · 159 · 394-409
DOI: 10.1016/j.actbio.2023.01.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Biomaterialia, 2023-03. Verfasst von Tao Sun und 10 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical & Aerospace Engineering Department, Benjamin M. Statler College of Engineering & Mineral Resources, West Virginia University, Morgantown, …. Hauptthemen laut MEDLINE: Vagus Nerve Stimulation. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIGMS NIH HHS, General Electric, Northwell Health Feinstein Institutes for Medical Research.
Abstract (Originalsprache)
Vagus nerve stimulation (VNS) is being actively explored as a treatment for multiple conditions as part of bioelectronic medicine research. Reliable and safe VNS in mouse models is a critical need for understanding mechanisms of these. We report on the development and evaluation of a microfabricated cuff electrode (MouseFlex) constructed of polyimide (PI) and with iridium oxide (IrOx) electrodes that is thermoformed to 86 µm ± 12 µm radius to interface the mouse cervical vagus nerve (r ≈ 50 µm). Innovative bench-top methods were used to evaluate the stimulation stability and electrochemical properties of electrodes. Our aggressive stimulation stability (Stim-Stab) test utilized 1 billion pulses at a 1000 Hz with a current density of 6.28 A/cm2 (1.51 mC/cm2/phase) delivering 3023 × 103 C/cm2 to evaluate electrode lifetimes, and all electrodes remained functional. We also investigated the effects of thermoforming on their impedance, charge storage capacity (CSC), and charge injection capacity (CIC). The modest changes in electrochemical properties indicate that the thermoforming process was well tolerated. Thermoformed electrode safety and efficacy were evaluated in-vivo by performing acute VNS in mice and monitoring their heart and respiration rate as biomarkers. Their electrochemical properties were also measured before, during and after VNS. Bradycardia and bradypnea were reliably induced at stimulation currents of 100 to 200 µA, well below the in-vivo CIC of ∼1250 µA (∼0.5 mC/cm2), supporting their safety and efficacy. The electrode impedance increased and CIC decreased during in-vivo use, but largely reversed these changes in in-vitro testing after enzymatic cleaning, supporting their tolerance for surgical use. STATEMENT OF SIGNIFICANCE: Vagus nerve stimulation (VNS) is a rapidly growing aspect of healthcare and bioelectronic medicine research. Reliable and safe VNS in mice with small diameter (d ≈ 100 µm) nerves has been a challenge due to achieving intimate contact with the nerve, and the stimulation stability of commonly used electrodes. We demonstrate a microfabricated (MouseFlex) cuff electrode constructed of polyimide with IrOx electrodes that is thermoformed to contact the mouse cervical vagus. Bench studies highlight the stimulation stability exceeded 109 pulses at 6.28 A/cm2 and their electrochemical properties were measured before, during, and after bench and nerve stimulation. Nerve stimulation induced bradycardia and bradypnea at currents below the in-vivo charge injection capacity, supporting their safety, efficacy, and tolerance for surgical handling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical & Aerospace Engineering Department, Benjamin M. Statler College of Engineering & Mineral Resources, West Virginia University, Morgantown, WV 26505, United States.
- Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, New York 11030, United States.
- Paradromics, Austin, TX 78759, United States.
- Electrical and Computer Engineering Department, University of Utah, Salt Lake City, UT 84112, United States; Applied Biosensors, Salt Lake City, UT 84115, United States.
- Mechanical & Aerospace Engineering Department, Benjamin M. Statler College of Engineering & Mineral Resources, West Virginia University, Morgantown, WV 26505, United States. Electronic address: loren.rieth@mail.wvu.edu.
Förderung
- NIGMS NIH HHS
- General Electric
- Northwell Health Feinstein Institutes for Medical Research
- United Therapeutics Corporation
- West Virginia University
- GE Global Research
Zitieren
APA
Sun, T., Tsaava, T., Peragine, J., Crosfield, C., Lopez, M. F., Modi, R., Sharma, R., Li, C., Sohal, H., Chang, E. H., & Rieth, L. (2023). Flexible IrOx neural electrode for mouse vagus nerve stimulation. Acta Biomaterialia, 159, 394-409. https://doi.org/10.1016/j.actbio.2023.01.026
Vancouver
Sun T, Tsaava T, Peragine J, Crosfield C, Lopez MF, Modi R, et al. Flexible IrOx neural electrode for mouse vagus nerve stimulation. Acta Biomaterialia. 2023;159:394-409. doi:10.1016/j.actbio.2023.01.026
BibTeX
@article{Sun2023,
author = {Sun, Tao and Tsaava, Téa and Peragine, Joanne and Crosfield, Christine and Lopez, Maria Fernanda and Modi, Romil and Sharma, Rohit and Li, Chunyan and Sohal, Harbaljit and Chang, Eric H and Rieth, Loren},
title = {Flexible IrOx neural electrode for mouse vagus nerve stimulation},
journal = {Acta Biomaterialia},
year = {2023},
volume = {159},
pages = {394--409},
doi = {10.1016/j.actbio.2023.01.026}
}
EUVIMED