Advancing neonatal care through non-invasive biochemical monitoring and diagnostics
Biosensors and Bioelectronics · 2027-02 · 317 · 119387
DOI: 10.1016/j.bios.2026.119387 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Hanbyeol Son und 3 weiteren Autor:innen. Beteiligte Einrichtung: Major of Human Bioconvergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, R…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit nennt 153 Literaturangaben. Gefördert von: National NanoFab Center, Korea Institute of Industrial Technology, Korea Basic Science Institute.
Abstract (Originalsprache)
Repeated blood sampling remains the basis of neonatal biochemical assessment, although it is painful and, in extremely preterm infants, removes close to one third of the circulating blood volume. Non-invasive biosensing offers alternatives, but most studies report analytical figures of merit or correlation with blood, which do not show whether a measurement meets the requirements of clinical use. This review maps neonatal biomarkers to saliva, sweat, tears, urine, and exhaled breath and to electrochemical, optical, and chemiresistive platforms, and compares their technical progress with the requirements of clinical use. Adapting established test-evaluation methodology, we define the evidence required for replacement, triage, add-on, monitoring, discovery, and diagnosis with matrix-native thresholds, and we add requirements specific to non-invasive matrices: sampling failure, variable matrix-to-blood ratios, and matrix confounders. Neonatal data show that the same statistic can lead to opposite conclusions, as salivary caffeine and C-reactive protein illustrate. Only sweat chloride and transcutaneous bilirubin are established in routine neonatal practice. Among representative custom-engineered devices, the evidence mostly stops at paired comparison in selected, case-control, or balanced samples, and performance in consecutively enrolled infants is rarely reported. For small molecules and electrolytes, progress now depends more on study design, namely consecutive enrollment and paired sampling at clinically indicated blood draws, than on further gains in analytical sensitivity. Extending the framework to early-life protection, we argue that a measurement protects an infant only when it detects change in time for an effective intervention, and that this chain is so far best supported within established screening pathways.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Major of Human Bioconvergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, Republic of Korea.
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA; Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems, Georgia I…
- Major of Human Bioconvergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, Republic of Korea; Digital Healthcare Research Center, Pukyong National…
Förderung
- National NanoFab Center
- Korea Institute of Industrial Technology
- Korea Basic Science Institute
Zitieren
APA
Son, H., Kim, D., Yeo, W. H., & Lim, H. R. (2027). Advancing neonatal care through non-invasive biochemical monitoring and diagnostics. Biosensors and Bioelectronics, 317, 119387. https://doi.org/10.1016/j.bios.2026.119387
Vancouver
Son H, Kim D, Yeo WH, Lim HR. Advancing neonatal care through non-invasive biochemical monitoring and diagnostics. Biosensors and Bioelectronics. 2027;317:119387. doi:10.1016/j.bios.2026.119387
BibTeX
@article{Son2027,
author = {Son, Hanbyeol and Kim, Doyoun and Yeo, W Hong and Lim, Hyo-Ryoung},
title = {Advancing neonatal care through non-invasive biochemical monitoring and diagnostics},
journal = {Biosensors and Bioelectronics},
year = {2027},
volume = {317},
pages = {119387},
doi = {10.1016/j.bios.2026.119387}
}
EUVIMED