Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Shaghayegh Mesforush und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Biosensing Techniques, Polyvinyl Alcohol. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Northeastern University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive wearable biopotential interfaces (WBIs), devices that enable recording of electrical signals from the body's surface, depend on electrodes that form a low impedance interface with the skin. Existing electrodes are often bulky, uncomfortable, slow to stabilize, and socially unacceptable due to their conspicuous appearance, or require complex conductive materials and fabrication processes. Here, we show that thin films of poly(vinyl alcohol) (PVA), a low-cost, transparent, electronically insulating biodegradable thermoplastic, can be used as a discreet, high-performance electrode when exposed to a water-based ionic gel. Water plasticizes PVA and makes it mechanically skin-like. Plasticized PVA also becomes ionically conductive to serve as an electrode that conforms to the skin to enable efficient ion transport at the skin's interface upon application, yielding 13× lower resistance than when the same gel is used with a plastic backing. This eliminates the stabilization delay of conventional wet or semi-wet electrodes, leading to a similar level of performance when compared to benchmark Ag/AgCl semi-wet electrodes for electrocardiography and electromyography, enabling the implementation of a wireless gesture recognition interface. Signal quality is maintained or improved over multi-hour recordings, and artificial sweat can replace the ionic gel to yield a comparable skin-electrode impedance. These results establish biodegradable thermoplastics as a scalable path towards socially acceptable, high-performance WBIs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesBiosensing TechniquesPolyvinyl AlcoholHumansWaterElectrodesEquipment DesignElectromyographyElectrocardiographyElectric Impedance

Stichwörter der Autor:innen

Biodegradable electronicsECGEMGImperceptible biosensorsTransparent electrodesWearable sensors

Substanzen

Polyvinyl AlcoholWater

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.
  • Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.
  • Department of Electrical and Computer Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA. Electronic address: c.fuentes@northeastern.edu.

Förderung

  • Northeastern University

Zitieren

APA

Mesforush, S., Pourjafarian, N., Wan, Y., Arjomandbigdeli, T., Bai, R., & Fuentes-Hernandez, C. (2027). Discreet wearable biopotential interfaces based on water-soluble biodegradable thermoplastics. Biosensors and Bioelectronics, 316, 119338. https://doi.org/10.1016/j.bios.2026.119338

Vancouver

Mesforush S, Pourjafarian N, Wan Y, Arjomandbigdeli T, Bai R, Fuentes-Hernandez C. Discreet wearable biopotential interfaces based on water-soluble biodegradable thermoplastics. Biosensors and Bioelectronics. 2027;316:119338. doi:10.1016/j.bios.2026.119338

BibTeX
@article{Mesforush2027,
  author = {Mesforush, Shaghayegh and Pourjafarian, Narges and Wan, Yichen and Arjomandbigdeli, Tara and Bai, Ruobing and Fuentes-Hernandez, Canek},
  title = {Discreet wearable biopotential interfaces based on water-soluble biodegradable thermoplastics},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {316},
  pages = {119338},
  doi = {10.1016/j.bios.2026.119338}
}
Kostenlos starten →