MXene-AuNP electrochemical aptasensor for dual-channel detection of insulin and glucose with HOMA-IR quantification
Biosensors and Bioelectronics · 2026-10 · 310 · 118856
DOI: 10.1016/j.bios.2026.118856 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-10. Verfasst von Maryam Awan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Clarkson University, 8 Clarkson Ave., Potsdam, NY, 13699, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Insulin, Metal Nanoparticles, Aptamers, Nucleotide. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Science Foundation, Clarkson University, National Science Foundation Division of Chemical Bioengineering Environmental and Transport Systems.
Abstract (Originalsprache)
The Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) is a critical clinical index for the early detection of IR and metabolic disorders; yet, its implementation as a point-of-care (POC) test remains limited by the lack of rapid platforms for insulin detection. Here, we report a Python-assisted electrochemical sensing platform for HOMA-IR evaluation based on multilayered Ti3C2Tx-MXene decorated with gold nanoparticles (MXene@AuNPs) and functionalized with methylene blue (MB)-labeled thiolated glucose and insulin aptamers, enabling dual-channel detection of glucose and insulin on screen-printed carbon electrodes (SPCE). The highly conductive MXene@AuNPs interface provides a large surface area and Au-S binding sites for stable immobilization of thiolated aptamers, while facilitating efficient electron transfer. Using differential pulse voltammetry (DPV), the platform enables sensitive detection of insulin and glucose, with detection limits of 0.32 μIU/mL and 18 mg/dL and linear response ranges of 1-50 μIU/mL and 50-300 mg/dL, respectively. Analysis of human serum samples demonstrates accurate quantification and high selectivity against common interferences. Integration of electrochemical sensing with Python-based data processing enables direct estimation of HOMA-IR values, providing a rapid electroanalytical POC evaluation of IR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, Clarkson University, 8 Clarkson Ave., Potsdam, NY, 13699, USA.
- Department of Chemistry and Biochemistry, Clarkson University, 8 Clarkson Ave., Potsdam, NY, 13699, USA; Kafkas University, Faculty of Medicine, Department of Medical Biochemistry, Kars, 36100, Türkiye.
- Department of Chemistry and Biochemistry, Clarkson University, 8 Clarkson Ave., Potsdam, NY, 13699, USA. Electronic address: eandrees@clarkson.edu.
Förderung
- National Science Foundation
- Clarkson University
- National Science Foundation Division of Chemical Bioengineering Environmental and Transport Systems
Zitieren
APA
Awan, M., Uygun, Z. O., Gondhiya, N., & Andreescu, S. (2026). MXene-AuNP electrochemical aptasensor for dual-channel detection of insulin and glucose with HOMA-IR quantification. Biosensors and Bioelectronics, 310, 118856. https://doi.org/10.1016/j.bios.2026.118856
Vancouver
Awan M, Uygun ZO, Gondhiya N, Andreescu S. MXene-AuNP electrochemical aptasensor for dual-channel detection of insulin and glucose with HOMA-IR quantification. Biosensors and Bioelectronics. 2026;310:118856. doi:10.1016/j.bios.2026.118856
BibTeX
@article{Awan2026,
author = {Awan, Maryam and Uygun, Zihni Onur and Gondhiya, Nishi and Andreescu, Silvana},
title = {MXene-AuNP electrochemical aptasensor for dual-channel detection of insulin and glucose with HOMA-IR quantification},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {310},
pages = {118856},
doi = {10.1016/j.bios.2026.118856}
}
EUVIMED