EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

MoS2-supported multiepitope protein electrochemical biosensors: A simple and highly selective approach for the diagnosis of systemic mycoses

Nicole G Maia, Amanda F Pereira, Jaqueline Volpe, Hélida M de Andrade, Rafael M S S Brandão, Liline Martins, Semiramis J H do Monte, Aldo J G Zarbin, Dênio E P Souto

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118761 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Nicole G Maia und 8 weiteren Autor:innen. Beteiligte Einrichtung: Laboratório de Espectrometria, Sensores e Biossensores (LaESB) - Department of Chemistry, Federal University of Paraná (UFPR), Curitiba, PR, 81530-90…. Hauptthemen laut MEDLINE: Biosensing Techniques, Molybdenum, Disulfides, Mycoses. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundacion Araucaria, CNPq, Fundação Araucária.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cryptococcosis is a life-threatening fungal infection with global public health impact, affecting both immunocompromised individuals and the general population. Accurate clinical management requires differentiation of Cryptococcus species and detection of subclinical infections. However, current diagnostic methods suffer from limited sensitivity and, notably, selectivity. Here, we report a highly sensitive and selective electrochemical immunosensor for rapid and simple serological diagnosis of cryptococcosis. The sensor employs novel multi-epitope chimeric proteins (A, B, C, and D) directly anchored onto a molybdenum disulfide (MoS2)-functionalized gold electrode, enabling simplified construction and stable bioreceptor immobilization without chemical cross-linkers. Comprehensive physicochemical characterization by SPR, AFM, EDS, SEM, Raman spectroscopy, and electrochemical techniques provided essential structural information governing the synergistic integration of MoS2 and chimeric proteins. Using Square Wave Voltammetry (SWV), a comparative evaluation against human serum samples identified Protein D as the main bioreceptor, providing the highest discrimination between positive and negative groups. The optimized MoS2/Protein D immunosensor achieved an outstanding limit of detection (LOD) of 0.124 fmol L-1 and a wide linear range spanning from fmol L-1 to nmol L-1. Clinical validation via ROC curve analysis demonstrated excellent diagnostic performance, with 100% sensitivity, 87.5% specificity, and an area under the curve (AUC) of 0.987. Furthermore, the sensor exhibited high selectivity against a panel of five other systemic mycoses (aspergillosis, histoplasmosis, sporotrichosis, coccidioidomycosis, and paracoccidioidomycosis), overcoming the specificity gaps of routine assays. These results represent a significant advance for clinical practice and highlight the potential of simple electrochemical approaches to resolve complex diagnostic problems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMolybdenumDisulfidesMycosesHumansElectrochemical TechniquesLimit of DetectionEpitopesGold

Stichwörter der Autor:innen

CryptococcosisElectrochemical immunosensorMolybdenum disulfideMulti-epitope proteinSquare wave voltammetry

Substanzen

MolybdenumDisulfidesmolybdenum disulfideEpitopesGold

Autor:innen und Institutionen

  • Laboratório de Espectrometria, Sensores e Biossensores (LaESB) - Department of Chemistry, Federal University of Paraná (UFPR), Curitiba, PR, 81530-900, Brazil.
  • Grupo de Química de Materiais (GQM), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba, PR, 81530-900, Brazil.
  • Laboratório de Leishmanioses, Department of Parasitology, Institute of Biological Sciences, Federal University of Minas Gerais (UFMG), Belo Horizonte, MG, 31270-901, Brazil.
  • Laboratório de Imunogenética e Biologia Molecular, Federal University of Piaui (UFPI), Teresina, PI, 64049-550, Brazil.
  • Laboratório de Espectrometria, Sensores e Biossensores (LaESB) - Department of Chemistry, Federal University of Paraná (UFPR), Curitiba, PR, 81530-900, Brazil. Electronic address: denio.souto@ufpr.br.

Förderung

  • Fundacion Araucaria
  • CNPq
  • Fundação Araucária
  • CAPES

Zitieren

APA

Maia, N. G., Pereira, A. F., Volpe, J., Andrade, H. M., M S S Brandão, R., Martins, L., Monte, S. J. H. D., Zarbin, A. J. G., & E P Souto, D. (2026). MoS2-supported multiepitope protein electrochemical biosensors: A simple and highly selective approach for the diagnosis of systemic mycoses. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118761

Vancouver

Maia NG, Pereira AF, Volpe J, Andrade HM, M S S Brandão R, Martins L, et al. MoS2-supported multiepitope protein electrochemical biosensors: A simple and highly selective approach for the diagnosis of systemic mycoses. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118761

BibTeX
@article{Maia2026,
  author = {Maia, Nicole G and Pereira, Amanda F and Volpe, Jaqueline and Andrade, Hélida M de and M S S Brandão, Rafael and Martins, Liline and Monte, Semiramis J H do and Zarbin, Aldo J G and E P Souto, Dênio},
  title = {MoS2-supported multiepitope protein electrochemical biosensors: A simple and highly selective approach for the diagnosis of systemic mycoses},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118761}
}
Kostenlos starten →