Electrochemical PSA Detection Performance of an Innovative Immunosensor
Langmuir · 2025
DOI: 10.1021/acs.langmuir.5c02632 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, 2025. Verfasst von Ahmet Şenocak und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Gebze Technical University, Gebze/Kocaeli 41400, Türkiye. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Karadeniz Teknik ?niversitesi.
Abstract (Originalsprache)
Prostate-specific antigen (PSA) is a protein produced by the prostate gland and is a critical biomarker for the early detection and monitoring of prostate cancer. Current methods in the detection of PSA include enzyme-linked immunosorbent assay (ELISA), chemiluminescent immunoassays (CLIA), and radioimmunoassay (RIA). They are expensive and time-consuming processes, even though they are considered the gold standard. On the other hand, biosensing technology is an emerging alternative method for the detection of PSA. Electrochemical immunosensor systems are widely used for detecting a variety of antigens with high selectivity and specificity. In this study, to prepare an immunosensor for PSA detection, a thiophene appended cobalt(II) phthalocyanine (CoPc), its polymer (Poly-Pc), and CuCoFe2O4@MoS2-NH2 were synthesized. Then, anti-PSA antibodies were immobilized on the CuCoFe2O4@MoS2-NH2-based Poly-Pc composite using glutaraldehyde as a cross-linker, and the immunosensor was prepared. Differential pulse voltammetry (DPV) employed to monitor the measurements showed that the proposed immunosensor system exhibited excellent analytical performance, with a wide linear detection range (0.01-1000 ng/mL) and a low detection limit of 6.3 pg/mL. The proposed immunosensor system offered high selectivity, reproducibility, and stability, even in complex biological samples such as synthetic serum, which was compared to a commercially available ELISA kit. The obtained results showed that the immunosensor has the potential to be used in clinical diagnosis as a rapid and reliable tool for PSA detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Gebze Technical University, Gebze/Kocaeli 41400, Türkiye.
- Biotechnology Institute, Gebze Technical University, Gebze/Kocaeli 41400, Türkiye.
- METU MEMS Center, Ankara 06530, Türkiye.
- Department of Chemistry, Faculty of Science, Hacettepe University, 06800 Ankara, Türkiye.
- Department of Chemistry, Atatürk University, Erzurum 25240, Türkiye.
- Department of Nanoscience and Nanoengineering, Atatürk University, Erzurum 25240, Türkiye.
ORCID-Profile: Ahmet Şenocak, Süreyya Oğuz Tümay, Ümit Demirbaş
Förderung
- Karadeniz Teknik ?niversitesi
Zitieren
APA
Şenocak, A., Kızılkurtlu, A. A., Sanko, V., Tümay, S. O., & Demirbaş, Ü. (2025). Electrochemical PSA Detection Performance of an Innovative Immunosensor. Langmuir. https://doi.org/10.1021/acs.langmuir.5c02632
Vancouver
Şenocak A, Kızılkurtlu AA, Sanko V, Tümay SO, Demirbaş Ü. Electrochemical PSA Detection Performance of an Innovative Immunosensor. Langmuir. 2025. doi:10.1021/acs.langmuir.5c02632
BibTeX
@article{enocak2025,
author = {Şenocak, Ahmet and Kızılkurtlu, Ahmet Akif and Sanko, Vildan and Tümay, Süreyya Oğuz and Demirbaş, Ümit},
title = {Electrochemical PSA Detection Performance of an Innovative Immunosensor},
journal = {Langmuir},
year = {2025},
doi = {10.1021/acs.langmuir.5c02632}
}
EUVIMED