EUVIMEDEUVIMED entdecken
Open Access

Label-free, non-optical detection of intact SARS-CoV-2 virions in native human saliva via microscale surface ion conduction

Sommer Osman, Sanduni U Devasinghe, Madison E Strait, Cicero C Pola, Delphine Dean, Carmen L Gomes, Robbyn K Anand

Biosensors and Bioelectronics · 2026-07 · 304 · 118643

DOI: 10.1016/j.bios.2026.118643 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-07. Verfasst von Sommer Osman und 6 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Chemistry, Iowa State University, 2415 Osborn Drive, 1605 Gilman Hall, Ames, IA, United States. Hauptthemen laut MEDLINE: Saliva, SARS-CoV-2, Biosensing Techniques, Virion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Clemson University, National Science Foundation Division of Chemistry.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The COVID-19 pandemic underscored the need for deployable point-of-care (POC) diagnostics capable of rapid viral detection in complex biofluids. While antigen-based tests offer advantages over reverse transcriptase polymerase chain reaction (RT-PCR) in speed and accessibility, many platforms remain limited by labeling requirements, optical readout, or sample pretreatment. Here, we report the first demonstration of label-free, non-optical, direct detection of intact SARS-CoV-2 virions in native human saliva without sample pretreatment using a microscale surface ion conduction (μSIC) sensor. This work further represents the first application of a μSIC sensor to clinical samples, validated using saliva from COVID-19 patients. In this approach, virions bind to a packed bed of probe-modified microbeads, producing a concentration-dependent shift in ionic current arising from modulation of surface ion conduction, even under high ionic strength conditions. The μSIC sensor achieves a limit of detection of 8.5 × 106 copies/mL for chemically inactivated virions, within clinically relevant concentration ranges, and delivers results within 1 h. Notably, the active virus in patient-derived saliva produces a significantly larger signal than the inactivated virus, consistent with inactivation-induced changes in antigen binding. The sensor exhibits high selectivity for SARS-CoV-2 in the presence of non-target human coronaviruses. These results demonstrate that specific binding of nanometer-scale virions can measurably alter ionic conductivity along microscale bead surfaces, enabling robust detection in native biofluids. Owing to its simplicity, adaptability, and compatibility with POC implementation, the μSIC platform provides a versatile framework for antigen-based diagnostics targeting emerging infectious diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaSARS-CoV-2Biosensing TechniquesVirionCOVID-19HumansLimit of DetectionRapid Diagnostic TestsElectric Conductivity

Stichwörter der Autor:innen

Intact SARS-CoV-2 virionIon conductionLabel-free sensingNative human saliva

Autor:innen und Institutionen

  • The Department of Chemistry, Iowa State University, 2415 Osborn Drive, 1605 Gilman Hall, Ames, IA, United States.
  • The Department of Mechanical Engineering, Iowa State University, 2025 Black Engineering, Ames, IA, United States; Department of Food Science and Human Nutrition, Iowa State University, 536 Farm House Ln, Ames, IA, Unite…
  • Department of Bioengineering, Clemson University, Clemson, SC, United States; Center for Innovative Medical Devices and Sensors (REDDI Lab), Clemson University, Clemson, SC, United States.
  • The Department of Mechanical Engineering, Iowa State University, 2025 Black Engineering, Ames, IA, United States.
  • The Department of Chemistry, Iowa State University, 2415 Osborn Drive, 1605 Gilman Hall, Ames, IA, United States. Electronic address: rkanand@iastate.edu.

Förderung

  • NIGMS NIH HHS
  • Clemson University
  • National Science Foundation Division of Chemistry
  • Roy J Carver Charitable Trust
  • National Institutes of Health
  • National Institute of General Medical Sciences

Zitieren

APA

Osman, S., Devasinghe, S. U., Strait, M. E., Pola, C. C., Dean, D., Gomes, C. L., & Anand, R. K. (2026). Label-free, non-optical detection of intact SARS-CoV-2 virions in native human saliva via microscale surface ion conduction. Biosensors and Bioelectronics, 304, 118643. https://doi.org/10.1016/j.bios.2026.118643

Vancouver

Osman S, Devasinghe SU, Strait ME, Pola CC, Dean D, Gomes CL, et al. Label-free, non-optical detection of intact SARS-CoV-2 virions in native human saliva via microscale surface ion conduction. Biosensors and Bioelectronics. 2026;304:118643. doi:10.1016/j.bios.2026.118643

BibTeX
@article{Osman2026,
  author = {Osman, Sommer and Devasinghe, Sanduni U and Strait, Madison E and Pola, Cicero C and Dean, Delphine and Gomes, Carmen L and Anand, Robbyn K},
  title = {Label-free, non-optical detection of intact SARS-CoV-2 virions in native human saliva via microscale surface ion conduction},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {304},
  pages = {118643},
  doi = {10.1016/j.bios.2026.118643}
}
Kostenlos starten →