Selective Wettability–Driven Evaporation‐Enhanced Redox Cycling for Robust and Ultrasensitive Detection of Viral Particles
Small Methods · 2026
DOI: 10.1002/smtd.202502229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small Methods, 2026. Verfasst von Pouya Soltan Khamsi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, SARS-CoV-2, Electrochemical Techniques, Influenza A Virus, H5N1 Subtype. Die Arbeit nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, Division of Electrical, Communications and Cyber Systems.
Abstract (Originalsprache)
Timely detection of viral infections, particularly in settings outside centralized laboratories, is essential for controlling outbreaks. Small electrochemical biosensors are appealing because they are fast, require microliter sample volumes, and can be integrated into portable devices. However, shrinking the sensor area often weakens the signal, making it difficult to detect low viral loads. We previously showed that combining redox cycling with controlled droplet evaporation can boost the signal. Yet, this method faces signal variability due to user‐dependent droplet placement. Here, we introduce a selective‐wettability, evaporation‐enhanced redox cycling (SW‐E2RC) device that passively centers and pins the droplet on the sensing area, improving both signal strength and reproducibility. The chip combines a wettable sensing zone surrounded by water‐repellent micropillars that guide the droplet into place and stabilize it during evaporation, concentrating redox‐active species over the electrodes. Using SARS‐CoV‐2 and avian influenza H5N1 as model pathogens, we show that SW‐E2RC reduces the LOD to 9.2 × 10 3 copies/mL, corresponding to a ∼10 3 ‐fold improvement in sensitivity compared with E2RC. This platform can be adapted to various capture probes and targets, enabling more sensitive and reliable point‐of‐need viral diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA.
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania, USA.
- Department of Infectious Diseases and Microbiology, School of Public Health, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
- Center for Vaccine Research, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA.
ORCID-Profile: Pouya Soltan Khamsi, Aida Ebrahimi
Förderung
- NIBIB NIH HHS
- NIH HHS
- Division of Electrical, Communications and Cyber Systems
- National Science Foundation
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Soltan Khamsi, P., Chothe, S. K., Kuchipudi, S. V., & Ebrahimi, A. (2026). Selective Wettability–Driven Evaporation‐Enhanced Redox Cycling for Robust and Ultrasensitive Detection of Viral Particles. Small Methods. https://doi.org/10.1002/smtd.202502229
Vancouver
Soltan Khamsi P, Chothe SK, Kuchipudi SV, Ebrahimi A. Selective Wettability–Driven Evaporation‐Enhanced Redox Cycling for Robust and Ultrasensitive Detection of Viral Particles. Small Methods. 2026. doi:10.1002/smtd.202502229
BibTeX
@article{SoltanKhamsi2026,
author = {Soltan Khamsi, Pouya and Chothe, Shubhada K and Kuchipudi, Suresh V and Ebrahimi, Aida},
title = {Selective Wettability–Driven Evaporation‐Enhanced Redox Cycling for Robust and Ultrasensitive Detection of Viral Particles},
journal = {Small Methods},
year = {2026},
doi = {10.1002/smtd.202502229}
}
EUVIMED