A bioreference electrode; a reference electrode which shifts its redox potential symmetrically with the working electrode to develop reliable bioelectrochemical sensors
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.118619 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Joseph A Kerrigan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Lampe Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, N…. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose, Burkholderia cepacia, Glucose 1-Dehydrogenase. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: University of North Carolina at Chapel Hill, ARKRAY, North Carolina State University.
Abstract (Originalsprache)
Potentiometric bioelectrochemical sensors offer advantages over amperometric ones due to their size-independent Nernstian response. However, their reliance on Ag/AgCl reference electrodes presents instabilities with environmental changes and prolonged use. Ag/AgCl instabilities are due to their reliance on a stable equilibrium between Ag+ and Cl- which may shift with fluctuations in chloride. To address this issue, we propose a reference electrode that incorporates an "inactivated" biological recognition element (inBRE) harboring identical redox species to the active BRE on the working electrode but lacking catalytic activity, thereby expecting a shift in its redox potential symmetrically with the working electrode, termed as a bioreference electrode. As proof of concept, we developed a potentiometric glucose bioelectrochemical sensor using a genetically and structurally inactivated direct electron transfer (DET)-type Burkholderia cepacia glucose dehydrogenase (inBcGDH) as the inBRE. Mutations (αHis476Ala/Asn519Ala) rendered BcGDH catalytically inactive while preserving its redox cofactors, creating a stable redox potential against which to measure. The inBcGDH was covalently immobilized on a 2 mm diameter gold electrode to form a bioreference electrode and integrated into an open-circuit potential (OCP)-based glucose sensor, which was evaluated for stability over 10 days and tested in various environmental factors (ionic strength, pH, and temperature) against traditional Ag/AgCl electrodes. Compared to Ag/AgCl, which experienced 67% signal loss over 10 days, the bioreference electrode exhibited only 23% loss. Additionally, after glucose addition (1 mM) in NaCl concentrations ranging from 50 to 500 mM, the bioreference electrode had only 6.2% signal bias, while Ag/AgCl showed up to 100% signal bias. Further, the bioreference electrode was able to be miniaturized using a 100 μm electrode, maintaining a linear signal response with glucose addition. These results demonstrate the bioreference electrode's ability to enhance potentiometric sensor stability and accuracy under varying conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Lampe Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA.
- Lampe Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA. Electronic address: ksode@email.unc.edu.
Förderung
- University of North Carolina at Chapel Hill
- ARKRAY
- North Carolina State University
Zitieren
APA
Kerrigan, J. A., Probst, D., & Sode, K. (2026). A bioreference electrode; a reference electrode which shifts its redox potential symmetrically with the working electrode to develop reliable bioelectrochemical sensors. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118619
Vancouver
Kerrigan JA, Probst D, Sode K. A bioreference electrode; a reference electrode which shifts its redox potential symmetrically with the working electrode to develop reliable bioelectrochemical sensors. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118619
BibTeX
@article{Kerrigan2026,
author = {Kerrigan, Joseph A and Probst, David and Sode, Koji},
title = {A bioreference electrode; a reference electrode which shifts its redox potential symmetrically with the working electrode to develop reliable bioelectrochemical sensors},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.118619}
}
EUVIMED