EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring

Mayank Garg, Heng Guo, Myeong Namkoong, Elizabeth Zhanov, Connor Malone, Md Saifur Rahman, Ayse Akcan-Arikan, Limei Tian

Biosensors and Bioelectronics · 2026-06 · 302 · 118519

DOI: 10.1016/j.bios.2026.118519 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-06. Verfasst von Mayank Garg und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX, 77843, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Troponin I, Myocardial Infarction. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, Texas A and M University, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac troponin I (cTnI) is the gold-standard biomarker for acute myocardial infarction, yet current laboratory-based high-sensitivity assays require centralized infrastructure, trained personnel, and serial testing, limiting their suitability for real-time or continuous monitoring in resource-limited settings. Point-of-care electrochemical sensors have shown promise for rapid cTnI detection, but their reliance on antibodies as biorecognition elements and redox mediator solutions, and single-use operation restricts practical translation. Here, we report an ultrasound-enabled refreshable electrochemical biosensor for sensitive, stable, and repeatable cTnI monitoring. The device employs a cTnI-specific peptide as the biorecognition element, providing enhanced stability during storage, transport, and operation. Label-free electrochemical impedance spectroscopy quantifies impedance changes upon cTnI binding in body fluids, including serum and saliva, enabling rapid analysis and high sensitivity with electroosmotic enhancement. The sensor achieves a wide dynamic range from 0.031 pg/mL to 1.5 ng/mL for cTnI detection and quantification in 15 min. Compared to previously reported electrochemical platforms and conventional laboratory-based high-sensitivity assays, the proposed sensor offers improved analytical performance, as defined by limit of detection, dynamic range, and assay time. Importantly, low-power ultrasound effectively refreshes the sensor by removing bound targets without damaging the peptide, enabling sustained measurements and prolonging sensor lifetime. The demonstrated sensitivity enhancement and refreshability establish a foundation for extending this approach to diverse biomarkers, paving the way for frequent molecular monitoring and early clinical intervention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesTroponin IMyocardial InfarctionHumansBiomarkersDielectric SpectroscopyLimit of DetectionEquipment DesignElectrochemical Techniques

Stichwörter der Autor:innen

Cardiac biomarkerComplex biofluidsElectrochemical biosensorRefreshableSensor regenerationUltrasound

Substanzen

Troponin IBiomarkers

Autor:innen und Institutionen

  • Department of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX, 77843, USA.
  • Department of Pediatrics, Divisions of Critical Care Medicine and Nephrology, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, 77030, USA.
  • Department of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX, 77843, USA. Electronic address: ltian@tamu.edu.

Förderung

  • NIGMS NIH HHS
  • Texas A and M University
  • National Institutes of Health
  • Texas A and M Engineering Experiment Station, Texas A and M University
  • National Science Foundation

Zitieren

APA

Garg, M., Guo, H., Namkoong, M., Zhanov, E., Malone, C., Rahman, M. S., Akcan-Arikan, A., & Tian, L. (2026). Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring. Biosensors and Bioelectronics, 302, 118519. https://doi.org/10.1016/j.bios.2026.118519

Vancouver

Garg M, Guo H, Namkoong M, Zhanov E, Malone C, Rahman MS, et al. Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring. Biosensors and Bioelectronics. 2026;302:118519. doi:10.1016/j.bios.2026.118519

BibTeX
@article{Garg2026,
  author = {Garg, Mayank and Guo, Heng and Namkoong, Myeong and Zhanov, Elizabeth and Malone, Connor and Rahman, Md Saifur and Akcan-Arikan, Ayse and Tian, Limei},
  title = {Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {302},
  pages = {118519},
  doi = {10.1016/j.bios.2026.118519}
}
Kostenlos starten →