A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface
Biosensors and Bioelectronics · 2026-06 · 301 · 118484
DOI: 10.1016/j.bios.2026.118484 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-06. Verfasst von Yang Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical Un…. Hauptthemen laut MEDLINE: Natriuretic Peptide, Brain, Biosensing Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: State Key Laboratory of Analytical Chemistry for Life Science, Natural Science Foundation of Guangxi Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
B-type natriuretic peptide (BNP) is an important biomarker for cardiovascular diseases, motivating sensitive and robust quantification in complex matrices. Here we report a single-electrode, anti-correlated dual-mode electrochemiluminescence/surface-enhanced Raman scattering (ECL/SERS) biosensor that couples split-aptamer recognition with a solution-phase T7 transcription-CRISPR/Cas13a cascade and an interfacial toehold-mediated strand-displacement "probe-stripping" transduction on a CsPbBr3@PDA@Au-modified glassy carbon electrode. BNP binding releases an active T7 template to generate trigger RNA, which activates Cas13a collateral cleavage to produce initiator strands for interfacial unlocking. The interface reaction removes ferrocene/Raman co-labeled probes, synchronizing ECL turn-on with SERS turn-off and enabling ratiometric quantification (R = IECL/ISERS) to suppress common-mode variability. The sensor provides BNP determination over 0-106 aM with log-linear single-mode calibrations and a continuous ratiometric response. Selectivity was validated against multiple interferents and the structurally related peptide NT-proBNP at the same concentration (106 aM), showing negligible ratiometric change relative to BNP. Serum-sample evaluation and stability tests further support feasibility in complex matrices. This work establishes a cascade-to-interface ratiometric strategy for robust protein biosensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University for Nationalities, BaiSe, Guangxi, 533000, China; Key Laborat…
- Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University for Nationalities, BaiSe, Guangxi, 533000, China.
- Key Laboratory of Guangxi's Colleges for the Study of Characteristic Ethnic Medicine in Youjiang River Basin, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. Electronic address: lxj2009919@…
- Institute of Advanced Materials and Flexible Electronics (IAMFE), School of Chemistry and Materials Science, Nanjing University of Information Science & Technology, Nanjing, Jiangsu, 210044, China. Electronic address: k…
- Key Laboratory of Guangxi's Colleges for the Study of Characteristic Ethnic Medicine in Youjiang River Basin, Youjiang Medical University for Nationalities, Baise, Guangxi, 533000, China. Electronic address: huanglongji…
- Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University for Nationalities, BaiSe, Guangxi, 533000, China. Electronic…
Förderung
- State Key Laboratory of Analytical Chemistry for Life Science
- Natural Science Foundation of Guangxi Province
- National Natural Science Foundation of China
Zitieren
APA
Li, Y., Ren, H., Wu, R., Wang, J., Gong, Y., Tang, Q., Liao, X., Zhang, K., Huang, L., & Wei, J. (2026). A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface. Biosensors and Bioelectronics, 301, 118484. https://doi.org/10.1016/j.bios.2026.118484
Vancouver
Li Y, Ren H, Wu R, Wang J, Gong Y, Tang Q, et al. A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface. Biosensors and Bioelectronics. 2026;301:118484. doi:10.1016/j.bios.2026.118484
BibTeX
@article{Li2026,
author = {Li, Yang and Ren, Haozhen and Wu, Runze and Wang, Jiahui and Gong, Yuanxun and Tang, Qianli and Liao, Xianjiu and Zhang, Kai and Huang, Longjian and Wei, Jihua},
title = {A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {301},
pages = {118484},
doi = {10.1016/j.bios.2026.118484}
}
EUVIMED