EUVIMEDEUVIMED entdecken
Crossref

An integrated pressure-based lateral flow immunoassay for microliter whole-blood AFP detection at the point of care

Gang Tang, Ke Liu, Lingying Xia, Tianhao Chen, Andrew Liman, Qiao Feng, Rongxing Zhou

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118398 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Gang Tang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Biliary Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China; Research Center for Biliary Dise…. Hauptthemen laut MEDLINE: alpha-Fetoproteins, Biosensing Techniques, Liver Neoplasms, Carcinoma, Hepatocellular. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Sichuan Provincial Science and Technology Support Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Alpha-fetoprotein (AFP) is a widely used biomarker for the diagnosis and postoperative surveillance of hepatocellular carcinoma (HCC). However, current AFP assays rely on centralized laboratories, bulky instrumentation, and labor-intensive sample pretreatment, limiting their applicability in point-of-care and home-based settings. Here, we present an in vitro diagnostic device for quantitative AFP detection in whole blood that integrates a lateral flow immunoassay (LFIA) with a portable pressure meter (PM-LFIA). The platform employs a pressure-based signal readout using nanozyme-catalyzed gas generation to enable sensitive quantification while reducing optical and matrix-related interference. Compared with conventional methods, the PM-LFIA platform achieves a 35-fold reduction in required sample volume and a 215-fold improvement in detection limit. The platform enables AFP detection from 1 μL of unprocessed whole blood within 30 min, supporting point-of-care applications where sample volume is limited. The feasibility of this approach was validated by direct quantification of AFP in 30 whole blood samples, with results consistent with hospital-based measurements. In addition, the applicability of the PM-LFIA platform was demonstrated for other cancer biomarkers, including CEA and CA199. Although environmental sensitivity and device calibration remain challenges, this work demonstrates an integrated and practical strategy for quantitative biomarker detection in whole blood using a portable, low-sample-volume format.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

alpha-FetoproteinsBiosensing TechniquesLiver NeoplasmsCarcinoma, HepatocellularBiomarkers, TumorHumansImmunoassayPoint-of-Care SystemsLimit of DetectionEquipment DesignRapid Diagnostic TestsPressure

Stichwörter der Autor:innen

Alpha-fetoproteinLateral flow immunoassayNanozymePoint-of-care testingWhole blood

Substanzen

alpha-FetoproteinsBiomarkers, Tumor

Autor:innen und Institutionen

  • Division of Biliary Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China; Research Center for Biliary Diseases, West China Hospital, Sichuan University, Chengdu, China.
  • Key Laboratory of Automobile Materials, Ministry of Education, School of Materials Science and Engineering, Jilin University, Changchun, China.
  • Division of Biliary Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China; Research Center for Biliary Diseases, West China Hospital, Sichuan University, Chengdu, China; Analyti…
  • Division of Biliary Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China; Research Center for Biliary Diseases, West China Hospital, Sichuan University, Chengdu, China. Electro…

Förderung

  • National Natural Science Foundation of China
  • Sichuan Provincial Science and Technology Support Program

Zitieren

APA

Tang, G., Liu, K., Xia, L., Chen, T., Liman, A., Feng, Q., & Zhou, R. (2026). An integrated pressure-based lateral flow immunoassay for microliter whole-blood AFP detection at the point of care. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118398

Vancouver

Tang G, Liu K, Xia L, Chen T, Liman A, Feng Q, et al. An integrated pressure-based lateral flow immunoassay for microliter whole-blood AFP detection at the point of care. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118398

BibTeX
@article{Tang2026,
  author = {Tang, Gang and Liu, Ke and Xia, Lingying and Chen, Tianhao and Liman, Andrew and Feng, Qiao and Zhou, Rongxing},
  title = {An integrated pressure-based lateral flow immunoassay for microliter whole-blood AFP detection at the point of care},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118398}
}
Kostenlos starten →