An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification

Peng Zhang, Chenqi Zhang, Min Jia, Yongdong Pan, Shuo Wu, Jianxin Cheng, Lujie Song, Zizhen Ming

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.345570 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Peng Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Electrical Engineering, North China University of Science and Technology, Tangshan 063210, China; Xiangfu Laboratory, Jiaxing Key Laborato…. Hauptthemen laut MEDLINE: alpha-Fetoproteins, Lab-On-A-Chip Devices, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Municipality Science and Technology Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early diagnosis of hepatocellular carcinoma (HCC) depends on rapid, sensitive, and reliable immunoassays; however, conventional ELISA techniques are often limited by complex manual operations, prolonged assay durations, and insufficient sensitivity, which significantly impede the detection of low-abundance biomarkers at the early disease stage. In contrast, microfluidic technology minimizes reagent consumption, enables precise spatiotemporal control of reactions, and provides a versatile platform for developing magnetically guided, multi-step immunoassay systems suited for portable, on-site screening applications. Herein, we have developed a portable microfluidic device with magnetic control, wherein an algorithm-driven stepper motor moves the microfluidic chip across a fixed magnetic-field array, thereby creating tunable local magnetic fields. This design integrates digital algorithmic control, mechanical actuation, the microfluidic chip, and functionalized magnetic beads into a seamless control chain, enabling full automation of bead capture, bead transport, and a sequence of immunoreaction steps without manual intervention. Using alpha-fetoprotein (AFP) as a model biomarker, the device achieved a detection limit of 119.43 ng/mL in the colorimetric measurement mode, and an impressive 3.66 ng/mL in the chemiluminescent mode. The results demonstrate the feasibility of automated, multi-step immunoassay processing in a compact point-of-care format, with potential applications in rapid and sensitive biomarker screening for early disease diagnosis. Importantly, this platform substantially fulfils pivotal deficiencies in HCC screening by markedly abbreviating assay duration and attenuating procedural complexity, thereby enhancing accessibility within resource-limited milieus. By facilitating antecedent detection at a juncture when curative interventions are optimally efficacious, it holds considerable promise for elevating patient prognoses, prolonging survival trajectories, and democratizing advanced diagnostic capabilities across broader populations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

alpha-FetoproteinsLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesHumansImmunoassayAutomationLiver NeoplasmsLimit of DetectionCarcinoma, HepatocellularRapid Diagnostic TestsColorimetry

Stichwörter der Autor:innen

Biomarkers detectionMicrofluidic chipOn-chip immunoassaysPoint-of-care testingPortable device

Substanzen

alpha-Fetoproteins

Autor:innen und Institutionen

  • College of Electrical Engineering, North China University of Science and Technology, Tangshan 063210, China; Xiangfu Laboratory, Jiaxing Key Laboratory of Bio-semiconductor, Jiashan 314102, China.
  • Xiangfu Laboratory, Jiaxing Key Laboratory of Bio-semiconductor, Jiashan 314102, China.
  • Center for Artificial Intelligence in Agriculture, Fujian Agriculture and Forestry University, Fuzhou 350000, China.
  • Department of Urology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200233, China.
  • Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Labora-tory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
  • Department of Urology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200233, China. Electronic address: ljsong@sjtu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Shanghai Municipality Science and Technology Commission

Zitieren

APA

Zhang, P., Zhang, C., Jia, M., Pan, Y., Wu, S., Cheng, J., Song, L., & Ming, Z. (2026). An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345570

Vancouver

Zhang P, Zhang C, Jia M, Pan Y, Wu S, Cheng J, et al. An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345570

BibTeX
@article{Zhang2026,
  author = {Zhang, Peng and Zhang, Chenqi and Jia, Min and Pan, Yongdong and Wu, Shuo and Cheng, Jianxin and Song, Lujie and Ming, Zizhen},
  title = {An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.345570}
}
Kostenlos starten →