EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Gas sensor for 4-ethylguaiacol detection based on tyrosinase enzymatic activity in a deep eutectic solvent

Paula Portugal-Gómez iD, Rossella Svigelj iD, Fabiola Zanette iD, Rosanna Toniolo iD, Olga Domínguez-Renedo iD, M Asunción Alonso-Lomillo iD

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07218-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Paula Portugal-Gómez und 5 weiteren Autor:innen. Beteiligte Einrichtung: Analytical Chemistry Department, Faculty of Sciences, University of Burgos, Pza. Misael Bañuelos S/N, 09001, Burgos, Spain. Hauptthemen laut MEDLINE: Monophenol Monooxygenase, Deep Eutectic Solvents, Guaiacol, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MCIU/AEI/10.13039/501100011033/FEDER,UE, Italian Ministry of University and Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of environmentally friendly, cost-effective and biodegradable deep eutectic solvents (DESs) as nonaqueous solvents and electrolytes offers a promising avenue for enhancing enzymatic sensors and extending their applicability to the gas phase. In this study, an assembly is presented that includes a paper crown modified with tyrosinase enzyme, soaked in a DES and positioned on a disposable screen-printed carbon electrode. The paper crown contacts the outer edge of the carbon disk working electrode, as well as the peripheral counter and reference electrodes. This assembly yields a portable and disposable electrochemical platform, effortlessly immobilising DESs onto a porous and economical supporting material like paper. Moreover, the entire configuration resulted in a sensitive, rapidly responsive, membrane-free gas sensor whose response time depended exclusively on the enzymatic reaction. The electroanalytical capabilities of this setup were evaluated through voltammetric and amperometric determinations of phenols in synthetic and real wine samples. The proposed gas enzymatic sensor demonstrated excellent analytical performance for detecting phenolic compounds, offering fast measurement times, simple operation, high sensitivity, wide linear range and good repeatability. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monophenol MonooxygenaseDeep Eutectic SolventsGuaiacolBiosensing TechniquesElectrodesElectrochemical TechniquesWineGasesEnzymes, ImmobilizedPaperLimit of Detection

Stichwörter der Autor:innen

Deep eutectic solventsGas sensorNanomaterialsPhenolsScreen-printed carbon electrodesWine analysis

Substanzen

Monophenol MonooxygenaseDeep Eutectic SolventsGuaiacolGasesEnzymes, Immobilized

Autor:innen und Institutionen

  • Analytical Chemistry Department, Faculty of Sciences, University of Burgos, Pza. Misael Bañuelos S/N, 09001, Burgos, Spain.
  • Department of Agrifood, Environmental and Animal Sciences, University of Udine, Via Cotonificio 108, 33100, Udine, Italy.
  • Department of Agrifood, Environmental and Animal Sciences, University of Udine, Via Cotonificio 108, 33100, Udine, Italy. rosanna.toniolo@uniud.it.
  • Analytical Chemistry Department, Faculty of Sciences, University of Burgos, Pza. Misael Bañuelos S/N, 09001, Burgos, Spain. malomillo@ubu.es.

ORCID-Profile: Paula Portugal-Gómez, Rossella Svigelj, Fabiola Zanette, Rosanna Toniolo, Olga Domínguez-Renedo, M Asunción Alonso-Lomillo

Förderung

  • MCIU/AEI/10.13039/501100011033/FEDER,UE
  • Italian Ministry of University and Research

Zitieren

APA

Portugal-Gómez, P., Svigelj, R., Zanette, F., Toniolo, R., Domínguez-Renedo, O., & Alonso-Lomillo, M. A. (2025). Gas sensor for 4-ethylguaiacol detection based on tyrosinase enzymatic activity in a deep eutectic solvent. Microchimica Acta. https://doi.org/10.1007/s00604-025-07218-6

Vancouver

Portugal-Gómez P, Svigelj R, Zanette F, Toniolo R, Domínguez-Renedo O, Alonso-Lomillo MA. Gas sensor for 4-ethylguaiacol detection based on tyrosinase enzymatic activity in a deep eutectic solvent. Microchimica Acta. 2025. doi:10.1007/s00604-025-07218-6

BibTeX
@article{PortugalGmez2025,
  author = {Portugal-Gómez, Paula and Svigelj, Rossella and Zanette, Fabiola and Toniolo, Rosanna and Domínguez-Renedo, Olga and Alonso-Lomillo, M Asunción},
  title = {Gas sensor for 4-ethylguaiacol detection based on tyrosinase enzymatic activity in a deep eutectic solvent},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07218-6}
}
Kostenlos starten →