A daily-durable wearable sweat biosensing device with robust reticular conductive biogel interface
Biosensors and Bioelectronics · 2026-03 · 296 · 118312
DOI: 10.1016/j.bios.2025.118312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-03. Verfasst von Qian Yu und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR …. Hauptthemen laut MEDLINE: Biosensing Techniques, Sweat, Wearable Electronic Devices, Glucose. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University State Key Laboratory of Analytical Chemistry for Life Sciences, National Natural Science Foundation of China.
Abstract (Originalsprache)
Wearable biosensing devices are essential for managing chronic diseases at home. However, their clinical translation has been hindered by the poor durability and stability of biosensors during long-term use in real-world scenarios. Here, we report a daily-durable wearable electrochemical biosensor array by encapsulating ZIF-90@enzymes within a conductive gel matrix to form a robust reticular biogel interface for continuous analysis of sweat glucose and lactate. The wearable biosensors exhibit exceptional environmental adaptability and durability, retaining >95 % sensitivity after summer outdoor exposure for 10 h and >85 % sensitivity after 1000 bends. In addition, they also demonstrate excellent pH and temperature tolerance, and the room-temperature storage stability of 140 days. By integrating the biosensor array with a paper-based sweat collector and a printed circuit board, the proposed wearable device enables on-body sweat analysis during both vigorous exercise (e.g., running) and daily activities, showing its application prospects in routine health monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR China.
- State Key Laboratory of Digital Medical Engineering, Southeast University, Nanjing, 211189, PR China.
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR China. Electronic address: wujie@nju.edu.cn.
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR China. Electronic address: hxju@nju.edu.cn.
Förderung
- State Key Laboratory of Analytical Chemistry for Life Science
- Nanjing University State Key Laboratory of Analytical Chemistry for Life Sciences
- National Natural Science Foundation of China
Zitieren
APA
Yu, Q., Sun, J., Yuan, C., Zhao, C., Chen, Y., Wu, J., Yu, S., Liu, H., & Ju, H. (2026). A daily-durable wearable sweat biosensing device with robust reticular conductive biogel interface. Biosensors and Bioelectronics, 296, 118312. https://doi.org/10.1016/j.bios.2025.118312
Vancouver
Yu Q, Sun J, Yuan C, Zhao C, Chen Y, Wu J, et al. A daily-durable wearable sweat biosensing device with robust reticular conductive biogel interface. Biosensors and Bioelectronics. 2026;296:118312. doi:10.1016/j.bios.2025.118312
BibTeX
@article{Yu2026,
author = {Yu, Qian and Sun, Jun and Yuan, Chen and Zhao, Chao and Chen, Yunlong and Wu, Jie and Yu, Siqi and Liu, Hong and Ju, Huangxian},
title = {A daily-durable wearable sweat biosensing device with robust reticular conductive biogel interface},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {296},
pages = {118312},
doi = {10.1016/j.bios.2025.118312}
}