Evaporation-driven digital ELISA with micro-droplet arrays for ultrafast detection of low-abundance proteins
Biosensors and Bioelectronics · 2026-01 · 292 · 118076
DOI: 10.1016/j.bios.2025.118076 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-01. Verfasst von Bo Hoon Han und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Brain Technology, Korea Institute of Science and Technology, Seoul, Republic of Korea; Department of Mechanical Engineering, Korea Univers…. Hauptthemen laut MEDLINE: Biosensing Techniques, Troponin I. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KIST, Ministry of Science and ICT, South Korea, National Research Foundation of Korea.
Abstract (Originalsprache)
Early detection of ultra-low-abundance protein biomarkers is critical for improving clinical outcomes. However, many conventional immunoassays and proteomic platforms exhibit high limits of detection (LOD) and long incubation times, complicating low-to sub-femtomolar measurements. In addition, state-of-the-art digital ELISAs often rely on magnetic beads, oil emulsions, and pump-valve benchtop analyzers-bulky and costly systems that hinder broad deployment. Here, we present a digital ELISA (dELISA) that lowers LOD and shortens time-to-result by harnessing rapid, repeated femtoliter-scale droplet evaporation on a bead-free, oil-free micro-droplet array. Cyclic ≈30-fL droplet generation/evaporation at the air-water interface enriches analytes at antibody-functionalized surfaces, while evaporation-induced convection and a shortened diffusion path increase antigen-antibody encounter frequency. For cardiac troponin I, the platform achieved an LOD of 64.23 fM with 300 evaporation cycles, a >280-fold improvement over 96-well ELISA. The same capture obtained after 120 min of static soaking occurred in 1.76 min with cyclic evaporation. Counts matched a Poisson capture model, with binding increasing linearly with cycle number. In diluted human plasma, the assay maintained >86 % recovery with minimal non-specific adsorption. Simple fabrication, the absence of beads, oils, and complex fluidic hardware, and high-throughput compatibility indicate strong potential for point-of-care use and integration into diverse digital immunoassay applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Brain Technology, Korea Institute of Science and Technology, Seoul, Republic of Korea; Department of Mechanical Engineering, Korea University, Seoul, Republic of Korea.
- Department of Mechanical Engineering, Korea University, Seoul, Republic of Korea.
- Center for Brain Technology, Korea Institute of Science and Technology, Seoul, Republic of Korea; Division of Bio-Medical Science and Technology, University of Science and Technology, Daejeon, Republic of Korea. Electro…
Förderung
- KIST
- Ministry of Science and ICT, South Korea
- National Research Foundation of Korea
Zitieren
APA
Han, B. H., Park, M., Chung, S., & Kang, J. Y. (2026). Evaporation-driven digital ELISA with micro-droplet arrays for ultrafast detection of low-abundance proteins. Biosensors and Bioelectronics, 292, 118076. https://doi.org/10.1016/j.bios.2025.118076
Vancouver
Han BH, Park M, Chung S, Kang JY. Evaporation-driven digital ELISA with micro-droplet arrays for ultrafast detection of low-abundance proteins. Biosensors and Bioelectronics. 2026;292:118076. doi:10.1016/j.bios.2025.118076
BibTeX
@article{Han2026,
author = {Han, Bo Hoon and Park, Minjun and Chung, Seok and Kang, Ji Yoon},
title = {Evaporation-driven digital ELISA with micro-droplet arrays for ultrafast detection of low-abundance proteins},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {292},
pages = {118076},
doi = {10.1016/j.bios.2025.118076}
}
EUVIMED