Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Maziar ShafieiDarabi und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON, N2L 3G1, Canada; University of Calgary, Department of El…. Hauptthemen laut MEDLINE: Biosensing Techniques, Amylases, Anastomotic Leak. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canada Excellence Research Chairs, Mitacs Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Anastomotic leakage (AL) is a serious complication following colorectal cancer surgery, resulting in increased morbidity, extended hospital stays, and higher mortality rates. Current methods for AL monitoring are often delayed, non-specific, and unsuitable for long-term point-of-care (POC) applications, highlighting the need for cost-effective, portable biosensors. Amylase, a promising biomarker present in peritoneal fluid, offers hope for early and long-term detection of AL. In this study, we present a miniaturized microwave biosensor capable of quasi-continuous (e.g. hourly) monitoring of amylase concentrations from postoperative day 1 and for a long time. The sensor detects clinically relevant amylase concentrations (>1000 U/L) within an hour, enabling early and prolonged monitoring of AL. High specificity was achieved using an amylopectin coating that reacts selectively with amylase, even in complex samples such as simulated peritoneal fluid (SPF). We validated the performance of our miniaturized, portable microwave sensor against the EnzChek™ Ultra Amylase Assay Kit, confirming its accuracy and reliability. This low-cost, portable biosensor provides a proof-of-concept for a practical, highly specific POC solution for real-time AL monitoring, supporting both early diagnosis and long-term postoperative care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAmylasesAnastomotic LeakMicrowavesHumansEquipment DesignPoint-of-Care Systems

Stichwörter der Autor:innen

Amylase detectionAnastomotic leakage (AL)Early detectionMicrowave biosensors

Substanzen

Amylases

Autor:innen und Institutionen

  • University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON, N2L 3G1, Canada; University of Calgary, Department of Electrical and Software Engineering, Calgary, AB, T2N 1N4, Canada.
  • University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON, N2L 3G1, Canada.
  • FluidAI Medical, Kitchener, ON, N2H 5L6, Canada.
  • University of Calgary, Department of Electrical and Software Engineering, Calgary, AB, T2N 1N4, Canada.
  • Harvard Medical School, Harvard University, Boston, MA, 02115, USA; Department of Medicine, Brigham and Women's Hospital, Boston, MA, 02115, USA. Electronic address: lplee@bwh.harvard.edu.
  • University of Waterloo, Department of Mechanical and Mechatronics Engineering, Waterloo, ON, N2L 3G1, Canada. Electronic address: c3ren@uwaterloo.ca.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Canada Excellence Research Chairs
  • Mitacs Inc

Zitieren

APA

ShafieiDarabi, M., Mao, Q., Cui, W., Courtney, M., Miranda, R., Ali, K., LeSergent, L., Tjandra, R., Abbasi, Z., Lee, L. P., & Ren, C. L. (2025). Microwave biosensor for amylase detection in drainage fluid to monitor anastomotic leakage. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117990

Vancouver

ShafieiDarabi M, Mao Q, Cui W, Courtney M, Miranda R, Ali K, et al. Microwave biosensor for amylase detection in drainage fluid to monitor anastomotic leakage. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117990

BibTeX
@article{ShafieiDarabi2025,
  author = {ShafieiDarabi, Maziar and Mao, Qianying and Cui, Weijia and Courtney, Matthew and Miranda, Robert and Ali, Kulsum and LeSergent, Lauren and Tjandra, Ricky and Abbasi, Zahra and Lee, Luke P and Ren, Carolyn L},
  title = {Microwave biosensor for amylase detection in drainage fluid to monitor anastomotic leakage},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117990}
}
Kostenlos starten →