EUVIMEDEUVIMED entdecken
Crossref

Singlicate bead-based immunoassay for biomarker quantitation in sub-microliter volume sample

Sang Hyun Lee, Myeongsik Shin, Chang Heon Lee, Taek Dong Chung

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117537 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Sang Hyun Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Seoul National University, Seoul, 08826, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Myoglobin. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-care testing (PoCT) devices are becoming increasingly essential for widespread disease diagnostics. Hence, it becomes necessary to develop solutions for detecting biomarkers from minimal-volume samples while remaining accessible and user-friendly. This study presents a new method called FoCUS (Forward scattering Correction Using a Single-bead). FoCUS combines tiny beads floating in liquid with a small chip to measure very small amounts of sample. It can analyze a single drop using just one bead. The platform employs a novel signal correction strategy to enhance fluorescence signal sensitivity using forward scattering signals obtained simultaneously. Compared to conventional methods, the FoCUS platform achieves a 1000-fold reduction in the required sample volume, a 2.7-fold decrease in the relative standard deviation of sample signals, and a 4.3-fold improvement in detection limits. The platform successfully detected relevant myoglobin levels from 0.1 μL of sample, demonstrating its potential for multiplex biomarker immunoassays in point-of-care applications where sample volumes are limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMyoglobinImmunoassayHumansBiomarkersLimit of DetectionEquipment DesignPoint-of-Care TestingPoint-of-Care Systems

Stichwörter der Autor:innen

Bead-based immunoassayForward scattering correctionMicrofluidicsSinglicateSubmicroliter analysis

Substanzen

BiomarkersMyoglobin

Autor:innen und Institutionen

  • Department of Chemistry, Seoul National University, Seoul, 08826, Republic of Korea.
  • Department of Chemistry, Seoul National University, Seoul, 08826, Republic of Korea. Electronic address: tdchung@snu.ac.kr.

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Lee, S. H., Shin, M., Lee, C. H., & Chung, T. D. (2025). Singlicate bead-based immunoassay for biomarker quantitation in sub-microliter volume sample. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117537

Vancouver

Lee SH, Shin M, Lee CH, Chung TD. Singlicate bead-based immunoassay for biomarker quantitation in sub-microliter volume sample. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117537

BibTeX
@article{Lee2025,
  author = {Lee, Sang Hyun and Shin, Myeongsik and Lee, Chang Heon and Chung, Taek Dong},
  title = {Singlicate bead-based immunoassay for biomarker quantitation in sub-microliter volume sample},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117537}
}
Kostenlos starten →