EUVIMEDEUVIMED entdecken
Crossref

An ultrasensitive diagnostic system for minuscule level of hemolytic uremic syndrome

Jai Eun An, Kyung-Soo Lee, Sung Eun Seo, Yoo Min Park, Kyong-Cheol Ko, Moo-Seung Lee, Oh Seok Kwon

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117893 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Jai Eun An und 6 weiteren Autor:innen. Beteiligte Einrichtung: SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, Republic of Korea; Korea Preclinical Evaluation Center, Kor…. Hauptthemen laut MEDLINE: Biosensing Techniques, Hemolytic-Uremic Syndrome, Enterohemorrhagic Escherichia coli, Escherichia coli Infections. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Ministry of Science and ICT, South Korea, National Research Foundation, Korea Research Institute of Bioscience and Biotechnology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemolytic uremic syndrome (HUS) is a life-threatening condition characterized by acute renal failure that is often caused by Shiga toxins (Stxs) produced by enterohemorrhagic Escherichia coli (EHEC). Early and precise diagnosis is critical for effective HUS treatment and the prevention of further severe complications. In this study, we present an ultrasensitive graphene-based field-effect transistor (FET)-based biosensor designed to detect trace levels of Stxs, aiming to improve HUS diagnosis. The sensor demonstrated exceptional sensitivity, with detection limits reaching the femtogram level, and outstanding specificity against nontarget molecules. Notably, this sensor operates without the need for fluorescent molecules, offering a simpler, cost-effective, and highly scalable alternative to fluorescence-based methods. Comprehensive laboratory evaluations revealed the rapid response time, high accuracy, and robustness of the sensor under diverse experimental conditions. The integration of the FET biosensor into diagnostic workflows offers a transformative approach to diagnosis, enabling earlier detection of Stxs and facilitating timely intervention for HUS. Furthermore, the incorporation of this sensor into clinical settings has potential at its early stages. These findings highlight the feasibility of translating this technology for routine clinical use, paving the way for more effective disease management in both hospital and point-of-care settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesHemolytic-Uremic SyndromeEnterohemorrhagic Escherichia coliEscherichia coli InfectionsShiga ToxinsHumansGraphiteLimit of DetectionTransistors, ElectronicEquipment Design

Stichwörter der Autor:innen

BiomarkerEarly stageHemolytic uremic syndromePoint-of-careShiga toxinsUltrasensitive

Substanzen

GraphiteShiga Toxins

Autor:innen und Institutionen

  • SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, Republic of Korea; Korea Preclinical Evaluation Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwa…
  • Environmental Diseases Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-Gu, Daejeon, 34141, Republic of Korea.
  • SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, Republic of Korea.
  • Center for Nano Bio Development National NanoFab Center (NNFC) 291 Daehakro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Korea Preclinical Evaluation Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Environmental Diseases Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-Gu, Daejeon, 34141, Republic of Korea; Department of Biomolecular Science, KRIBB School of Bioscie…

Förderung

  • Ministry of Science and ICT, South Korea
  • National Research Foundation
  • Korea Research Institute of Bioscience and Biotechnology
  • Ministry of Food and Drug Safety

Zitieren

APA

An, J. E., Lee, K. S., Seo, S. E., Park, Y. M., Ko, K. C., Lee, M. S., & Kwon, O. S. (2025). An ultrasensitive diagnostic system for minuscule level of hemolytic uremic syndrome. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117893

Vancouver

An JE, Lee KS, Seo SE, Park YM, Ko KC, Lee MS, et al. An ultrasensitive diagnostic system for minuscule level of hemolytic uremic syndrome. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117893

BibTeX
@article{An2025,
  author = {An, Jai Eun and Lee, Kyung-Soo and Seo, Sung Eun and Park, Yoo Min and Ko, Kyong-Cheol and Lee, Moo-Seung and Kwon, Oh Seok},
  title = {An ultrasensitive diagnostic system for minuscule level of hemolytic uremic syndrome},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117893}
}
Kostenlos starten →