Touch-based uric acid sweat biosensor towards personal health and nutrition
Biosensors and Bioelectronics · 2025-06 · 277 · 117289
DOI: 10.1016/j.bios.2025.117289 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-06. Verfasst von Chochanon Moonla und 4 weiteren Autor:innen. Beteiligte Einrichtung: Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, CA, 92093, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Sweat, Uric Acid. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Higher Education Commision, Pakistan, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, University of California San Diego.
Abstract (Originalsprache)
Monitoring uric acid (UA) levels is critical since elevated UA levels are associated with diverse conditions, such as gout, kidney disorders, kidney stones, hypertension, cardiovascular diseases, and metabolic syndrome. Maintaining balanced UA levels demands reliable and regular monitoring. Traditionally, such frequent UA measurements rely on blood-based UA self-testing strips. Developing sensitive and reliable noninvasive sweat-based UA sensors presents challenges, including the low UA sweat concentrations and interpersonal variations. We present here an attractive on-site UA self-testing approach utilizing a touch-enabled fingertip sweat UA electrochemical biosensor based on a uricase-enzyme electrode and sweat wicking hydrogel. This noninvasive method is rapid, simple, convenient, and painless, leveraging the high sweat rate on the fingertip at rest without any sweat stimulation. The touch-based protocol exhibits a wide linear range of UA concentrations from 10 to 1000 μM, covering normal and elevated UA sweat levels with high selectivity, reproducibility (RSD = 4.94%), good storage stability (1 week), and significant tolerance to temperature and humidity variations. The performance of the UA-touch sweat biosensor was evaluated and validated by parallel blood meter measurements by monitoring dynamically-changing sweat UA levels in healthy subjects after consuming purine-rich meals. The distinct sweat UA temporal profiles among individuals highlight the potential of the touch-based UA biosensor for personal health and nutrition. The speed and simplicity of this sweat UA assay thus encourage frequent self-testing and enhance user's compliance towards dietary interventions and lifestyle changes in connection to diverse healthcare and nutrition applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, CA, 92093, USA.
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, CA, 92093, USA. Electronic address: josephwang@ucsd.edu.
Förderung
- Higher Education Commision, Pakistan
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
- University of California San Diego
Zitieren
APA
Moonla, C., Khan, M. I., Akgonullu, S., Saha, T., & Wang, J. (2025). Touch-based uric acid sweat biosensor towards personal health and nutrition. Biosensors and Bioelectronics, 277, 117289. https://doi.org/10.1016/j.bios.2025.117289
Vancouver
Moonla C, Khan MI, Akgonullu S, Saha T, Wang J. Touch-based uric acid sweat biosensor towards personal health and nutrition. Biosensors and Bioelectronics. 2025;277:117289. doi:10.1016/j.bios.2025.117289
BibTeX
@article{Moonla2025,
author = {Moonla, Chochanon and Khan, Muhammad Inam and Akgonullu, Semra and Saha, Tamoghna and Wang, Joseph},
title = {Touch-based uric acid sweat biosensor towards personal health and nutrition},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {277},
pages = {117289},
doi = {10.1016/j.bios.2025.117289}
}
EUVIMED