Ultrasensitive point-of-care multiplex diagnosis for influenza virus based robust quantum dot microsphere-lateral flow immunoassay
Biosensors and Bioelectronics · 2025-04 · 273 · 117187
DOI: 10.1016/j.bios.2025.117187 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-04. Verfasst von Yuning Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Key Lab for Special Functional Materials of Ministry of Education, and School of Nanoscience and Materials Engineering, Henan University, 475004, Kai…. Hauptthemen laut MEDLINE: Quantum Dots, Biosensing Techniques, Influenza, Human, Influenza A virus. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Henan Provincial Science and Technology Research Project, Science and Technology Department of Henan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Influenza A virus (IAV) and influenza B virus (IBV) with similar symptoms of infection caused a serious disease burden and economic losses in annual epidemic season, so it is important to quickly and accurately detect and distinguish between IAV and IBV during influenza season. Herein, the quantum dot microspheres (QDMS) were synthesized and applied to lateral flow immunoassays (LFIA), and a point-of-care (POC) biosensor that can discriminately and simultaneously diagnose IAV and IBV within 10 min was established. A double-sandwich QDMS nanotags was synthesized by immobilizing hydrophobic quantum dots (QDs) with chemical bonding method on a silica sphere template with an outer silica shell protection showed excellent stability and high fluorescence. The highly sensitive quantitative detection is achieved with the tailored hand-hold detector. The limit of detection (LOD) of the LFIA based QDMS for the simultaneous detection of IAV and IBV were 0.080 ng/mL and 0.096 ng/mL, respectively. The QDMS-LFIA system has excellent specificity and stability for quantitative detection, especially showing good accuracy for clinical samples. Furthermore, the visualization sensitivity of the low-cost biosensor was improved by nearly an order of magnitude than gold nanoparticles (AuNP)-LFIA within shorter detection time. Given the excellent performance, our proposed QDMS-LFIA biosensor can potentially be applied to the POC sensitive discriminate and simultaneous detection of IAV and IBV in epidemic season.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Lab for Special Functional Materials of Ministry of Education, and School of Nanoscience and Materials Engineering, Henan University, 475004, Kaifeng, China.
- Beijing Lumitest biotechnology co., ltd, 100191, Beijing, China.
- Department of laboratory medicine, Chongqing General Hospital, School of Medicine, Chongqing University, Chongqing, 401147, China. Electronic address: wzhzeng@cqu.edu.cn.
- Monash Institute of Pharmaceutical Sciences (MIPS), Monash University, 3052, Parkville, VIC, Australia. Electronic address: qitong.feng@monash.edu.
- Key Lab for Special Functional Materials of Ministry of Education, and School of Nanoscience and Materials Engineering, Henan University, 475004, Kaifeng, China. Electronic address: wrl0378@henu.edu.cn.
- Key Lab for Special Functional Materials of Ministry of Education, and School of Nanoscience and Materials Engineering, Henan University, 475004, Kaifeng, China. Electronic address: lsli@henu.edu.cn.
Förderung
- Henan Provincial Science and Technology Research Project
- Science and Technology Department of Henan Province
- National Natural Science Foundation of China
Zitieren
APA
Zhang, Y., Lv, Y., Chen, X., Ye, Y., Yu, S., Li, N., Yao, H., Wang, Z., Feng, Q., Wu, R., & Li, L. S. (2025). Ultrasensitive point-of-care multiplex diagnosis for influenza virus based robust quantum dot microsphere-lateral flow immunoassay. Biosensors and Bioelectronics, 273, 117187. https://doi.org/10.1016/j.bios.2025.117187
Vancouver
Zhang Y, Lv Y, Chen X, Ye Y, Yu S, Li N, et al. Ultrasensitive point-of-care multiplex diagnosis for influenza virus based robust quantum dot microsphere-lateral flow immunoassay. Biosensors and Bioelectronics. 2025;273:117187. doi:10.1016/j.bios.2025.117187
BibTeX
@article{Zhang2025,
author = {Zhang, Yuning and Lv, Yanbing and Chen, Xinxin and Ye, Yingli and Yu, Shenping and Li, Ning and Yao, Hongtao and Wang, Zhizeng and Feng, Qitong and Wu, Ruili and Li, Lin Song},
title = {Ultrasensitive point-of-care multiplex diagnosis for influenza virus based robust quantum dot microsphere-lateral flow immunoassay},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {273},
pages = {117187},
doi = {10.1016/j.bios.2025.117187}
}
EUVIMED