EUVIMEDEUVIMED entdecken
Crossref

Digital Counting of Quantum Dots Nanobeads on Lateral Flow Test Strips Enables Ultrasensitive Point-of-Care Diagnostics

Wannian Yan iD, Wenwen Xia, Qinglei Hu, Shaoqun Zeng iD, Huanxing Han, Pengfei Zhang iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c00036 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Wannian Yan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China. Hauptthemen laut MEDLINE: Quantum Dots, Point-of-Care Systems, Interleukin-6, Reagent Strips. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Science and Technology Innovation Plan Of Shanghai Science and Technology Commission, Clinical Research Incubation Program of Shanghai Skin Disease Hospital, Medicine + X Interdisciplinary Project of Tongji University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lateral flow assay (LFA) is a versatile platform for the rapid detection of various pathogens, pollutants, and toxins at point of care (POC). However, a traditional lateral flow assay strip is still not sensitive enough for early detection of disease, and previous works to enhance the sensitivity of LFA systems have suffered from additional signal amplification chemistry, tedious operation procedure, or expensive signal amplification instruments. In this study, we introduced a digital counting strategy for signal measurement to improve the detection sensitivity of quantum dot nanobead-based lateral flow immunoassays, offering an alternative to traditional fluorescence intensity-based quantification. The ultrasensitive single-molecule POC detection system is composed of an ultrabright fluorescent quantum dot nanobead-based lateral flow assay strip and a portable fluorescent microscopy reader for numerating single immunocomplexes on a test line. As a proof-of-concept, we performed digital LFA to detect interleukin-6 in 1% BSA with LoD as low as 0.02 pg/mL, which is ∼100 times more sensitive than analog LFA. Moreover, an amplification-free assay for HIV RNA was also demonstrated by combining CRISPR-Cas13 reaction and digital LFA with a sensitivity of as low as 89 copies/mL. A prototype portable and affordable fluorescent microscopy reader was designed and demonstrated its ability to be used for on-site testing. All in all, the developed digital LFA system not only has single-molecule level sensitivity but also satisfies the rapidity, easy operation, portability, and low-cost requirements for POC testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quantum DotsPoint-of-Care SystemsInterleukin-6Reagent StripsImmunoassayHumansRapid Diagnostic TestsRNA, ViralLimit of Detection

Substanzen

Interleukin-6RNA, ViralReagent Strips

Autor:innen und Institutionen

  • Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China.
  • Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China.
  • Meca (Wuhan) Technology Co., Ltd., Wuhan 430074, China.
  • Tinyphoton (Wuhan) Technology Co., Ltd., Wuhan 430074, China.
  • Britton Chance Center and MoE Key Laboratory for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.

ORCID-Profile: Wannian Yan, Shaoqun Zeng, Pengfei Zhang

Förderung

  • Science and Technology Innovation Plan Of Shanghai Science and Technology Commission
  • Clinical Research Incubation Program of Shanghai Skin Disease Hospital
  • Medicine + X Interdisciplinary Project of Tongji University
  • Projects of International Cooperation and Exchanges

Zitieren

APA

Yan, W., Xia, W., Hu, Q., Zeng, S., Han, H., & Zhang, P. (2026). Digital Counting of Quantum Dots Nanobeads on Lateral Flow Test Strips Enables Ultrasensitive Point-of-Care Diagnostics. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c00036

Vancouver

Yan W, Xia W, Hu Q, Zeng S, Han H, Zhang P. Digital Counting of Quantum Dots Nanobeads on Lateral Flow Test Strips Enables Ultrasensitive Point-of-Care Diagnostics. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c00036

BibTeX
@article{Yan2026,
  author = {Yan, Wannian and Xia, Wenwen and Hu, Qinglei and Zeng, Shaoqun and Han, Huanxing and Zhang, Pengfei},
  title = {Digital Counting of Quantum Dots Nanobeads on Lateral Flow Test Strips Enables Ultrasensitive Point-of-Care Diagnostics},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c00036}
}
Kostenlos starten →