Ti3C2 MXene/GNRs for synergistically highly enhanced sensitivity of optical fiber SPR acetylcholine biosensors via an electrostatic layer-by-layer assembly method
Biosensors and Bioelectronics · 2025-04 · 273 · 117146
DOI: 10.1016/j.bios.2025.117146 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-04. Verfasst von Yumei Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: China School of Physical Science and Technology, Lanzhou University, Lanzhou, 730000, China; National Engineering Research Center of Fiber Optic Sens…. Hauptthemen laut MEDLINE: Acetylcholine, Surface Plasmon Resonance, Biosensing Techniques, Titanium. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Science and Technology Program of Gansu Province, Science and Technology Department of Gansu Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Improving the sensitivity of biosensor has always the major challenge to measure lower detection concentration of biological samples. In this paper, a novel optical fiber surface plasmon resonance (SPR) biosensor based on Ti3C2 MXene/GNRs synergistically highly enhanced sensitivity was proposed. The Ti3C2 MXene and GNRs were coated on the optical fiber sensing probe by the electrostatic layer-by-layer (ELBL) assembly method. The sensitivity of this optical fiber sensor was significantly improvement by 217.73% which largely benefited from the synergistic interaction between the increases of depth of evanescent wave and enhancement local electromagnetic field. The biosensors were successfully used to the high sensitivity detection of acetylcholine by immobilizing AchE as specific biorecognition molecules on the probe surface with PDA as the enzyme immobilization carrier. The sensitivity and LOD of the proposed biosensor for acetylcholine were 0.04521 nm/μM and 4.42 μM, respectively. The recovery rate of the biosensor in the actual samples detection were between 96 and 106%, and the response time was 220s. The proposed biosensor will provide a promising rapidly and accurately method for the detection of neurotransmitters in the clinic diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- China School of Physical Science and Technology, Lanzhou University, Lanzhou, 730000, China; National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 43…
- China School of Physical Science and Technology, Lanzhou University, Lanzhou, 730000, China.
- The First Hospital of Lanzhou University, Lanzhou, 730000, China.
- Innovation Center of Functional Genomics and Molecular Diagnostics Technology of Gansu Province, Lanzhou, China.
Förderung
- Science and Technology Program of Gansu Province
- Science and Technology Department of Gansu Province
- National Natural Science Foundation of China
Zitieren
APA
Zhang, Y., Ding, L., Xiao, B., Wang, S., Meng, W., Gao, L., Che, T., & Zheng, X. (2025). Ti3C2 MXene/GNRs for synergistically highly enhanced sensitivity of optical fiber SPR acetylcholine biosensors via an electrostatic layer-by-layer assembly method. Biosensors and Bioelectronics, 273, 117146. https://doi.org/10.1016/j.bios.2025.117146
Vancouver
Zhang Y, Ding L, Xiao B, Wang S, Meng W, Gao L, et al. Ti3C2 MXene/GNRs for synergistically highly enhanced sensitivity of optical fiber SPR acetylcholine biosensors via an electrostatic layer-by-layer assembly method. Biosensors and Bioelectronics. 2025;273:117146. doi:10.1016/j.bios.2025.117146
BibTeX
@article{Zhang2025,
author = {Zhang, Yumei and Ding, Liyun and Xiao, Baoquan and Wang, Shiyuan and Meng, Wenbo and Gao, Long and Che, Tuanjie and Zheng, Xiaoling},
title = {Ti3C2 MXene/GNRs for synergistically highly enhanced sensitivity of optical fiber SPR acetylcholine biosensors via an electrostatic layer-by-layer assembly method},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {273},
pages = {117146},
doi = {10.1016/j.bios.2025.117146}
}
EUVIMED