EUVIMEDEUVIMED entdecken
Crossref

Numerical study of a D-shaped optical fiber SPR biosensor for monitoring refractive index variations in biological tissue via a thin layer of gold coated with titanium dioxide

Ahmed Akouibaa, Abdelilah Akouibaa, Rachid Masrour, Mabrouk Benhamou, Abdellah Rezzouk

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024

DOI: 10.1016/j.saa.2023.123358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2024. Verfasst von Ahmed Akouibaa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Solid Physics, Faculty of Sciences Dhar El Mahraz, Sidi Mohamed Ben Abdellah University, BP 1796 Fez, Morocco. Hauptthemen laut MEDLINE: Titanium, Surface Plasmon Resonance, Gold, Optical Fibers. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 60 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to explore the numerical analysis of the impact of integrating titanium oxide (TiO2) into a D-shaped optical fiber biosensor based on surface plasmon resonance (SPR). A thin layer of gold (Au) is applied to the flat section of the fiber, which is also coated with a thin layer of titanium dioxide (TiO2). The behavior and performance of the proposed biosensor for use in biological environments are evaluated using the finite element method (FEM). The optical response of SPR-based biosensors is highly dependent on the analyzed medium, enabling the detection of pathogenic cells and abnormalities in biological tissues. This provides high sensitivity and selectivity, as well as real-time detection accuracy and speed. In this study, the biosensor is incorporated into a biological medium with a refractive index that varies with wavelength. A series of simulations have been conducted to plot the spectra of transmissions, absorptions, and dielectric losses obtained in the output of the sensor instrument. From these spectra, the corresponding surface plasmon resonance (SPR) wavelength (λSPR) within the visible-near-infrared band can be determined. Taking into account the various parameters that influence plasmonic interactions, the biosensor's performance parameters, in particular sensitivity and refractive index resolution have been optimized. Our results show that the presence of the TiO2 layer improves the performance of the proposed sensor and offers the possibility of adjusting the resonance wavelength (λSPR). In addition, our proposed sensor can achieve a better resolution of 7.50×10-6[RIU] in 1.34-143 range of analyte refractive index, which notably exceeds that of current technologies. This opens up new prospects in the field of chemical and biological detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumSurface Plasmon ResonanceGoldOptical FibersRefractometryBiosensing TechniquesHumansFinite Element Analysis

Stichwörter der Autor:innen

FEMFiber optic sensorOptical propertiesSensitivitySurface plasmon resonance biosensor

Substanzen

Titaniumtitanium dioxideGold

Autor:innen und Institutionen

  • Laboratory of Solid Physics, Faculty of Sciences Dhar El Mahraz, Sidi Mohamed Ben Abdellah University, BP 1796 Fez, Morocco.
  • LPPSMM, Physics Department, Faculty of Sciences Ben M'Sik, Hassan II University Casablanca, P.O. Box 7955, Casablanca, Morocco.
  • Laboratory of Solid Physics, Faculty of Sciences Dhar El Mahraz, Sidi Mohamed Ben Abdellah University, BP 1796 Fez, Morocco. Electronic address: rachidmasrour@hotmail.com.
  • Dynamics of Complex Systems Team, Physics Department, Faculty of Sciences, Moulay Ismail University, P.O. Box 11201, Meknes, Morocco.

Zitieren

APA

Akouibaa, A., Akouibaa, A., Masrour, R., Benhamou, M., & Rezzouk, A. (2024). Numerical study of a D-shaped optical fiber SPR biosensor for monitoring refractive index variations in biological tissue via a thin layer of gold coated with titanium dioxide. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2023.123358

Vancouver

Akouibaa A, Akouibaa A, Masrour R, Benhamou M, Rezzouk A. Numerical study of a D-shaped optical fiber SPR biosensor for monitoring refractive index variations in biological tissue via a thin layer of gold coated with titanium dioxide. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2024. doi:10.1016/j.saa.2023.123358

BibTeX
@article{Akouibaa2024,
  author = {Akouibaa, Ahmed and Akouibaa, Abdelilah and Masrour, Rachid and Benhamou, Mabrouk and Rezzouk, Abdellah},
  title = {Numerical study of a D-shaped optical fiber SPR biosensor for monitoring refractive index variations in biological tissue via a thin layer of gold coated with titanium dioxide},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2024},
  doi = {10.1016/j.saa.2023.123358}
}
Kostenlos starten →