Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone
Biosensors and Bioelectronics · 2025-03 · 272 · 117113
DOI: 10.1016/j.bios.2024.117113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-03. Verfasst von Wan-Zheng Fang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological Science and Technology, Institute of Molecular Medicine and Bioengineering, Center for Intelligent Drug Systems and Smart Bi…. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal-Organic Frameworks, Anti-Mullerian Hormone. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH2 was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH2 by in situ method for the first time. MOF matrix could be established to form a three-dimensional (3D) core-shell hybrid unit using MOFs with distinct characteristics. The morphology, structural characteristics, and electrochemical performance of MIL-88 B@UiO66NH2 were studied. It was successfully used for AMH sensing to demonstrate the detection performance of the internal extended growth method (IEGM) grown MIL-88 B@UiO66NH2 made immunosensor. The electrochemical results indicated that MOF-on-MOF exhibited linear EIS response for AMH concentration varying from 100 ng/mL to 1 fg/mL. Further, the immunosensor displayed high specificity and sensitivity for AMH detection. The fabricated sensor attained a remarkable limit of detection (LOD) of 1.07 fg/mL and 0.82 fg/mL, when studied in PBS and 10% serum buffer media, respectively. The biosensor achieved the limit of quantification (LOQ) of 3.25 fg/mL and 2.5 fg/mL, respectively, when analyzed in PBS buffer and 10% serum buffer. The significant results emphasized that the fabricated biosensor holds a promising potential to act as an appropriate tool for rapid assessment of AMH levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biological Science and Technology, Institute of Molecular Medicine and Bioengineering, Center for Intelligent Drug Systems and Smart Bio-devices (IDS(2)B), Yang Ming Chiao Tung University, Hsinchu 300, Tai…
- Department of Medical Imaging, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan; School of Post-Baccalaureate Medicine, College of Medicine, Drug Development and Value Creation Research Center, Kaohsiung Med…
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan; Department of Obstetrics and Gynecology, Hsinchu MacKay Memorial Hospital, Hsinchu 300, Taiwan; Department of Obstetrics and Gynecology, Hsinc…
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan 350, Taiwan. Electronic address: cyang@nhri.edu.tw.
Zitieren
APA
Fang, W. Z., Palanisamy, S., Vijayaraghavan, P., Chen, C. Y., Weng, S. L., Yang, C. S., & Wang, Y. M. (2025). Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone. Biosensors and Bioelectronics, 272, 117113. https://doi.org/10.1016/j.bios.2024.117113
Vancouver
Fang WZ, Palanisamy S, Vijayaraghavan P, Chen CY, Weng SL, Yang CS, et al. Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone. Biosensors and Bioelectronics. 2025;272:117113. doi:10.1016/j.bios.2024.117113
BibTeX
@article{Fang2025,
author = {Fang, Wan-Zheng and Palanisamy, Sathyadevi and Vijayaraghavan, Priya and Chen, Chiao-Yun and Weng, Shun-Long and Yang, Chung-Shi and Wang, Yun-Ming},
title = {Construction of in situ modulated controlled growth of MOF-on-mof impedimetric assembly for the practical minimal level assessment of anti-mullerian hormone},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {272},
pages = {117113},
doi = {10.1016/j.bios.2024.117113}
}
EUVIMED