EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive detection of holoTC for analysis of Vitamin B12 levels using Ag2MoO4 deposited PEDOT sensing platform

Rishika Rohilla, Amandeep Kaur, Sonia Rani, Nirmal Prabhakar

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2024.116783 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Rishika Rohilla und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry, Panjab University, Chandigarh, 160014, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Transcobalamins, Polymers, Vitamin B 12. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: CSIR, Panjab University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vitamin B12 is an essential micronutrient required for the proper functioning of the human body. Vitamin B12 deficiency is primarily causative of various neurolological disorders alongwith recurrence of oral ulcers and burning sensations which are early signs of condition such as pernicious anemia. Other complications associated with Vitamin B12 deficiency include risk of heart failure due to anemia, risk of developing autoimmune disorders and gastric cancer. Therefore, to obstruct these communal health issues, early detection of Vit B12 is highly needed. However, screening of vitamin B12 insufficiency is hindered by the low sensitivity of the conventional vitamin B12 test. Holotranscobalamin (holoTC) is an early indicator of the negative vitamin B12 balance as it is the first protein to decline in the serum. We report a novel impedimetric immunosensor based on flower-like poly (3,4-ethylenedioxythiophene) (PEDOT) nanostructural film impregnated with silver molybdate nanoparticles (Ag2MoO₄ NPs) deposited on fluorine-doped tin oxide electrode. The prepared electrodes were characterized by Field emission scanning electron microscopy (FE-SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and electrochemical studies. The activated anti-holoTC antibody was immobilized and optimized to capture the target in a response time of 15 min. The electrochemical performance of the sensor was carried out by using the electrochemical impedance spectroscopy technique (EIS) and a good linear relationship between ΔRct and holoTC was obtained in the range from 0.1 pg mL-1 to 100 ng mL-1 with a detection limit of 0.093 pg mL-1. The proposed sensor was successfully applied in human serum samples for holoTC detection. The experimental results showed that the immunosensor is highly selective towards holoTC and presented an acceptable stability of 20 days with reproducibility RSD ≤4%. To the best of our knowledge, this is the first developed electrochemical immunosensor for holoTC detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesTranscobalaminsPolymersVitamin B 12Limit of DetectionHumansMolybdenumElectrochemical TechniquesSilverAntibodies, ImmobilizedImmunoassayVitamin B 12 DeficiencyMetal NanoparticlesSilver CompoundsBridged Bicyclo Compounds, Heterocyclic

Stichwörter der Autor:innen

AntibodyElectrochemical immunosensorHolotranscobalaminPEDOTSilver molybdateVitamin B12

Substanzen

TranscobalaminsPolymersVitamin B 12poly(3,4-ethylene dioxythiophene)MolybdenumSilvermolybdateAntibodies, ImmobilizedSilver CompoundsBridged Bicyclo Compounds, Heterocyclic

Autor:innen und Institutionen

  • Department of Biochemistry, Panjab University, Chandigarh, 160014, India.
  • Department of Biochemistry, Panjab University, Chandigarh, 160014, India; Department of Chemistry and Centre for Advanced Studies in Chemistry, Panjab University, Chandigarh, 160014, India.
  • Department of Biochemistry, Panjab University, Chandigarh, 160014, India. Electronic address: nirmalprabhakar@gmail.com.

Förderung

  • CSIR
  • Panjab University

Zitieren

APA

Rohilla, R., Kaur, A., Rani, S., & Prabhakar, N. (2025). Ultrasensitive detection of holoTC for analysis of Vitamin B12 levels using Ag2MoO4 deposited PEDOT sensing platform. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116783

Vancouver

Rohilla R, Kaur A, Rani S, Prabhakar N. Ultrasensitive detection of holoTC for analysis of Vitamin B12 levels using Ag2MoO4 deposited PEDOT sensing platform. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116783

BibTeX
@article{Rohilla2025,
  author = {Rohilla, Rishika and Kaur, Amandeep and Rani, Sonia and Prabhakar, Nirmal},
  title = {Ultrasensitive detection of holoTC for analysis of Vitamin B12 levels using Ag2MoO4 deposited PEDOT sensing platform},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2024.116783}
}
Kostenlos starten →