EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

All-MXene electronic tongue for neurotransmitters detection

Murilo H M Facure, Gulnaz Gahramanova, Danzhen Zhang, Teng Zhang, Christopher E Shuck, Luiza A Mercante, Daniel S Correa, Yury Gogotsi

Biosensors and Bioelectronics · 2024-10 · 262 · 116526

DOI: 10.1016/j.bios.2024.116526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Murilo H M Facure und 7 weiteren Autor:innen. Beteiligte Einrichtung: Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, Sao Carlos, SP, Brazil; PPGQ, Department of Chemistry, …. Hauptthemen laut MEDLINE: Neurotransmitter Agents, Biosensing Techniques, Electronic Nose. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: FAPESP, National Science Foundation, Fulbright Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neurotransmitters (NTs) are molecules produced by neurons that act as the body's chemical messengers. Their abnormal levels in the human system have been associated with many disorders and neurodegenerative diseases, which makes the monitoring of NTs fundamentally important. Specifically for clinical analysis and understanding of brain behavior, simultaneous detection of NTs at low levels quickly and reliably is imperative for disease prevention and early diagnosis. However, the methods currently employed are usually invasive or inappropriate for multiple NTs detection. Herein, we developed a MXene-based impedimetric electronic tongue (e-tongue) for sensitive NT monitoring, using Nb2C, Nb4C3, Mo2C, and Mo2Ti2C3 MXenes as sensing units of the e-tongue, and Principal Component Analysis (PCA) as the data treatment method. The high specific surface area, distinct electrical properties, and chemical stability of the MXenes gave rise to high sensitivity and good reproducibility of the sensor array toward NT detection. Specifically, the e-tongue detected and differentiated multiple NTs (acetylcholine, dopamine, glycine, glutamate, histamine, and tyrosine) at concentrations as low as 1 nmol L-1 and quantified NTs present in a mixture. Besides, analyses performed with interferents and actual samples confirmed the system's potential to be used in clinical diagnostics. The results demonstrate that the MXene-based e-tongue is a suitable, rapid, and simple method for NT monitoring with high accuracy and sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neurotransmitter AgentsBiosensing TechniquesElectronic NoseHumansEquipment DesignPrincipal Component AnalysisLimit of Detection

Stichwörter der Autor:innen

2D materialsElectrical impedanceMXenesMolybdenum carbideNeurotransmitter sensingNiobium carbideSensor array

Substanzen

Neurotransmitter Agents

Autor:innen und Institutionen

  • Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, Sao Carlos, SP, Brazil; PPGQ, Department of Chemistry, Center for Exact Sciences and Technology, Federal University of Sao Ca…
  • A. J. Drexel Nanomaterials Institute and Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA; French-Azerbaijani University, 183 Nizami Str., AZ1000, Baku, Azerbaijan.
  • A. J. Drexel Nanomaterials Institute and Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA.
  • Institute of Chemistry, Federal University of Bahia (UFBA), 40170-280, Salvador, BA, Brazil.
  • A. J. Drexel Nanomaterials Institute and Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104, USA. Electronic address: gogotsi@drexel.edu.

Förderung

  • FAPESP
  • National Science Foundation
  • Fulbright Association

Zitieren

APA

Facure, M. H. M., Gahramanova, G., Zhang, D., Zhang, T., Shuck, C. E., Mercante, L. A., Correa, D. S., & Gogotsi, Y. (2024). All-MXene electronic tongue for neurotransmitters detection. Biosensors and Bioelectronics, 262, 116526. https://doi.org/10.1016/j.bios.2024.116526

Vancouver

Facure MHM, Gahramanova G, Zhang D, Zhang T, Shuck CE, Mercante LA, et al. All-MXene electronic tongue for neurotransmitters detection. Biosensors and Bioelectronics. 2024;262:116526. doi:10.1016/j.bios.2024.116526

BibTeX
@article{Facure2024,
  author = {Facure, Murilo H M and Gahramanova, Gulnaz and Zhang, Danzhen and Zhang, Teng and Shuck, Christopher E and Mercante, Luiza A and Correa, Daniel S and Gogotsi, Yury},
  title = {All-MXene electronic tongue for neurotransmitters detection},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {262},
  pages = {116526},
  doi = {10.1016/j.bios.2024.116526}
}
Kostenlos starten →