Methods for Estimating the Detection and Quantification Limits of Key Substances in Beer Maturation with Electronic Noses
Sensors · 30.05.2024 · 24 (11) · 3520
DOI: 10.3390/s24113520 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 30.05.2024. Verfasst von Julia Kruse und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Life Science Technologies (ILT.NRW), OWL University of Applied Sciences and Arts, 32657 Lemgo, Germany. Hauptthemen laut MEDLINE: Beer, Electronic Nose, Principal Component Analysis, Limit of Detection. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Culture and Science of the State of Northrhine Westphalia, Germany, SAIL: SustAInable Life-cycle of Intelligent Socio-Technical Systems, “Netzwerke 2021” of the Ministry of Culture and Science of the State of Northrhine Westphalia, Germany.
Abstract (Originalsprache)
To evaluate the suitability of an analytical instrument, essential figures of merit such as the limit of detection (LOD) and the limit of quantification (LOQ) can be employed. However, as the definitions k nown in the literature are mostly applicable to one signal per sample, estimating the LOD for substances with instruments yielding multidimensional results like electronic noses (eNoses) is still challenging. In this paper, we will compare and present different approaches to estimate the LOD for eNoses by employing commonly used multivariate data analysis and regression techniques, including principal component analysis (PCA), principal component regression (PCR), as well as partial least squares regression (PLSR). These methods could subsequently be used to assess the suitability of eNoses to help control and steer processes where volatiles are key process parameters. As a use case, we determined the LODs for key compounds involved in beer maturation, namely acetaldehyde, diacetyl, dimethyl sulfide, ethyl acetate, isobutanol, and 2-phenylethanol, and discussed the suitability of our eNose for that dertermination process. The results of the methods performed demonstrated differences of up to a factor of eight. For diacetyl, the LOD and the LOQ were sufficiently low to suggest potential for monitoring via eNose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Life Science Technologies (ILT.NRW), OWL University of Applied Sciences and Arts, 32657 Lemgo, Germany.
- Institute Industrial IT (inIT), OWL University of Applied Sciences and Arts, 32657 Lemgo, Germany.
ORCID-Profile: Julia Kruse, Julius Wörner, Miriam Pein-Hackelbusch
Förderung
- Ministry of Culture and Science of the State of Northrhine Westphalia, Germany
- SAIL: SustAInable Life-cycle of Intelligent Socio-Technical Systems
- “Netzwerke 2021” of the Ministry of Culture and Science of the State of Northrhine Westphalia, Germany
Zitieren
APA
Kruse, J., Wörner, J., Schneider, J., Dörksen, H., & Pein-Hackelbusch, M. (2024). Methods for Estimating the Detection and Quantification Limits of Key Substances in Beer Maturation with Electronic Noses. Sensors, 24(11), 3520. https://doi.org/10.3390/s24113520
Vancouver
Kruse J, Wörner J, Schneider J, Dörksen H, Pein-Hackelbusch M. Methods for Estimating the Detection and Quantification Limits of Key Substances in Beer Maturation with Electronic Noses. Sensors. 2024;24(11):3520. doi:10.3390/s24113520
BibTeX
@article{Kruse2024,
author = {Kruse, Julia and Wörner, Julius and Schneider, Jan and Dörksen, Helene and Pein-Hackelbusch, Miriam},
title = {Methods for Estimating the Detection and Quantification Limits of Key Substances in Beer Maturation with Electronic Noses},
journal = {Sensors},
year = {2024},
volume = {24},
number = {11},
pages = {3520},
doi = {10.3390/s24113520}
}