Development of DNA aptamers universally bound to single-chain fragment variables and their applications in bioprocess monitoring
Biosensors and Bioelectronics · 2024
DOI: 10.1016/j.bios.2024.116511 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Mai Hamasaki und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Kogan…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Single-Chain Antibodies, ErbB Receptors. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Student Services Organization, North Carolina State University, Tokyo University of Agriculture and Technology.
Abstract (Originalsprache)
Single-chain fragment variables (scFvs), composed of variable heavy and light chains joined together by a peptide linker, can be produced using a cost-effective bacterial expression system, making them promising candidates for pharmaceutical applications. However, a versatile method for monitoring recombinant-protein production has not yet been developed. Herein, we report a novel anti-scFv aptamer-based biosensing system with high specificity and versatility. First, anti-scFv aptamers were screened using the competitive systematic evolution of ligands by exponential enrichment, focusing on a unique scFv-specific peptide linker. We selected two aptamers, P1-12 and P2-63, with KD = 2.1 μM or KD = 1.6 μM toward anti-human epidermal growth factor receptor (EGFR) scFv, respectively. These two aptamers can selectively bind to scFv but not to anti-EGFR Fv. Furthermore, the selected aptamers recognized various scFvs with different CDRs, such as anti-4-1BB and anti-hemoglobin scFv, indicating that they recognized a unique peptide linker region. An electrochemical sensor for anti-EGFR scFv was developed using anti-scFv aptamers based on square wave voltammetry. Thus, the constructed sensor could monitor anti-EGFR scFv concentrations in the range of 10-500 nM in a diluted medium for bacterial cultivation, which covered the expected concentration range for the recombinant production of scFvs. These achievements promise the realization of continuous monitoring sensors for pharmaceutical scFv, which will enable the real-time and versatile monitoring of large-scale scFv production.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan; Joint Department of Biomedical Engineering…
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan.
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA.
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan. Electronic address: ikebu@cc.tuat.ac.jp.
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA. Electronic address: ksode@email.unc.edu.
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan; Institute of Global Innovation Research, T…
Förderung
- Japan Student Services Organization
- North Carolina State University
- Tokyo University of Agriculture and Technology
- Japan Society for the Promotion of Science
- University of North Carolina at Chapel Hill
- Department of Biomedical Engineering, Case Western Reserve University
- Takeda Science Foundation
Zitieren
APA
Hamasaki, M., Takamatsu, S., Nagata, M., Wilson, E., Suzuki, H., Tanaka, A., Ikebukuro, K., Sode, K., & Asano, R. (2024). Development of DNA aptamers universally bound to single-chain fragment variables and their applications in bioprocess monitoring. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116511
Vancouver
Hamasaki M, Takamatsu S, Nagata M, Wilson E, Suzuki H, Tanaka A, et al. Development of DNA aptamers universally bound to single-chain fragment variables and their applications in bioprocess monitoring. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116511
BibTeX
@article{Hamasaki2024,
author = {Hamasaki, Mai and Takamatsu, Shouhei and Nagata, Madoka and Wilson, Ellie and Suzuki, Hirobumi and Tanaka, Ayumi and Ikebukuro, Kazunori and Sode, Koji and Asano, Ryutaro},
title = {Development of DNA aptamers universally bound to single-chain fragment variables and their applications in bioprocess monitoring},
journal = {Biosensors and Bioelectronics},
year = {2024},
doi = {10.1016/j.bios.2024.116511}
}