EUVIMEDEUVIMED entdecken
Crossref

Detection of aldehydes from degradation of lipid nanoparticle formulations using a hierarchically-organized nanopore electrochemical biosensor

Julius Reitemeier, Jarek Metro, Paul W Bohn

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116457 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Julius Reitemeier und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, United States. Hauptthemen laut MEDLINE: Biosensing Techniques, Aldehydes, Nanopores, Nanoparticles. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: NSF, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Degradation of ionizable lipids in mRNA-based vaccines was recently found to deactivate the payload, demanding rigorous monitoring of impurities in lipid nanoparticle (LNP) formulations. However, parallel screening for lipid degradation in customized delivery systems for next-generation therapeutics maintains a challenging and unsolved problem. Here, we describe a nanopore electrochemical sensor to detect ppb-levels of aldehydes arising from lipid degradation in LNP formulations that can be deployed in massively parallel fashion. Specifically, we combine nanopore electrodes with a block copolymer (BCP) membrane capable of hydrophobic gating of analyte transport between the bulk solution and the nanopore volume. By incorporating aldehyde dehydrogenase (ALDH), enzymatic oxidation of aldehydes generates NADH to enable ultrasensitive voltammetric detection with limits-of-detection (LOD) down to 1.2 ppb. Sensor utility was demonstrated by detecting degradation of N-oxidized SM-102, the ionizable lipid in Moderna's SpikeVax™ vaccine, in mRNA-1273 LNP formulation. This work should be of significant use in the pharmaceutical industry, paving the way for automated on-line quality assessments of next-generation therapeutics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAldehydesNanoporesNanoparticlesElectrochemical TechniquesLipidsLimit of DetectionAldehyde DehydrogenaseLiposomes

Stichwörter der Autor:innen

BiosensorsBlock copolymersElectrochemistryLipid nanoparticlesNanopores

Substanzen

AldehydesLipidsAldehyde DehydrogenaseLipid NanoparticlesLiposomes

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, United States.
  • Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, United States; Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, United States…

Förderung

  • NSF
  • National Science Foundation

Zitieren

APA

Reitemeier, J., Metro, J., & Bohn, P. W. (2024). Detection of aldehydes from degradation of lipid nanoparticle formulations using a hierarchically-organized nanopore electrochemical biosensor. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116457

Vancouver

Reitemeier J, Metro J, Bohn PW. Detection of aldehydes from degradation of lipid nanoparticle formulations using a hierarchically-organized nanopore electrochemical biosensor. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116457

BibTeX
@article{Reitemeier2024,
  author = {Reitemeier, Julius and Metro, Jarek and Bohn, Paul W},
  title = {Detection of aldehydes from degradation of lipid nanoparticle formulations using a hierarchically-organized nanopore electrochemical biosensor},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116457}
}
Kostenlos starten →