EUVIMEDEUVIMED entdecken
Crossref

A label-free electrochemical biosensor based on graphene quantum dots-nanoporous gold nanocomposite for highly sensitive detection of glioma cell

Xiaohui Wang, Xinran Li, Baoquan Wang, Yanxia Xie, Xueru Cui, Jin Jiao, Jianwei Jiao, Yachao Zhang

Analytica Chimica Acta · 2025-02 · 1337 · 343555

DOI: 10.1016/j.aca.2024.343555 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-02. Verfasst von Xiaohui Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Life Sciences, The Second Affiliated Hospital, Medical Science and Technology Innovation Center, Shandong First Medical University & Shando…. Hauptthemen laut MEDLINE: Graphite, Quantum Dots, Biosensing Techniques, Glioma. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Glioma accounts for 80 % of all malignant primary brain tumors with a high mortality rate. Histopathological examination is the current diagnostic methods for glioma, but its invasive surgical interventions can cause cerebral edema or impair neural functioning. Liquid biopsy proves to be an efficient method for glioma detection. However, the blood-brain barrier restricts the number of circulating tumor cells (CTCs) in the bloodstream, posing a challenge for sensitive detection of glioma CTCs. This study aims to use the unique characteristics of nanocomposites and the specificity of Angiopep2 (Ang-2) to develop a method that can sensitively identify glioma CTCs. RESULTS: Herein, a novel label-free impedimetric biosensor was successfully constructed for glioma CTCs detection by using graphene quantum dots (GQDs)-nanoporous gold (NPG) nanocomposites as the immobilized platform and the Ang-2 protein as biorecognition element. The GQDs was homogeneously assembled onto NPG, resulting in the creation of a novel GQDs-NPG nanocomposite with unique structure and function properties. Due to the high electron transfer efficiency of the GQDs-NPG nanocomposite, the developed biosensor exhibited a wild detection range from 1 to 1 × 106 cell mL-1, with a minimal detection limit of 1 cell mL-1. Additionally, the glioma cell biosensor demonstrated a strong anti-interference ability against multiple cell lines, and the stability of the biosensor remained at 96 % after 21 days of storage. Besides, the quantities of glioma cells detected in human serum samples by the glioma cell biosensor demonstrated outstanding consistency with the standard values added to the samples. SIGNIFICANCE: The study provided a novel GQDs-NPG nanocomposite and an electrochemical biosensor based on GQDs-NPG was firstly developed for glioma CTCs detection. The glioma cell biosensor showed high sensitivity, low detection limit, strong anti-interference ability, and good stability in complex biological matrix. The reliable detection of glioma cell was successfully realized in human serum, providing an excellent option for liquid biopsy of glioma CTCs identification and early diagnosis of glioma diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteQuantum DotsBiosensing TechniquesGliomaNanocompositesElectrochemical TechniquesNeoplastic Cells, CirculatingBrain NeoplasmsHumansGoldLimit of DetectionCell Line, TumorNanopores

Stichwörter der Autor:innen

Angiopep2BiosensorCirculating tumor cellsGlioma cellGraphene quantum dotsNanoporous gold

Substanzen

GraphiteGold

Autor:innen und Institutionen

  • School of Life Sciences, The Second Affiliated Hospital, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250117, PR China; College of Li…
  • School of Life Sciences, The Second Affiliated Hospital, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250117, PR China.
  • Shandong Hongkui Medical Laboratory Co., Ltd. Jinan, 271100, PR China.
  • School of Life Sciences, The Second Affiliated Hospital, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250117, PR China. Electronic ad…
  • State Key Laboratory of Stem Cell and Reproductive Biology, Institute of Zoology, Chinese Academy of Sciences, Beijing, 100101, PR China. Electronic address: jwjiao@ioz.ac.cn.

Zitieren

APA

Wang, X., Li, X., Wang, B., Xie, Y., Cui, X., Jiao, J., Jiao, J., & Zhang, Y. (2025). A label-free electrochemical biosensor based on graphene quantum dots-nanoporous gold nanocomposite for highly sensitive detection of glioma cell. Analytica Chimica Acta, 1337, 343555. https://doi.org/10.1016/j.aca.2024.343555

Vancouver

Wang X, Li X, Wang B, Xie Y, Cui X, Jiao J, et al. A label-free electrochemical biosensor based on graphene quantum dots-nanoporous gold nanocomposite for highly sensitive detection of glioma cell. Analytica Chimica Acta. 2025;1337:343555. doi:10.1016/j.aca.2024.343555

BibTeX
@article{Wang2025,
  author = {Wang, Xiaohui and Li, Xinran and Wang, Baoquan and Xie, Yanxia and Cui, Xueru and Jiao, Jin and Jiao, Jianwei and Zhang, Yachao},
  title = {A label-free electrochemical biosensor based on graphene quantum dots-nanoporous gold nanocomposite for highly sensitive detection of glioma cell},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1337},
  pages = {343555},
  doi = {10.1016/j.aca.2024.343555}
}
Kostenlos starten →