Catalytic hairpin assembly-based AIEgen/graphene oxide nanocomposite for fluorescence-enhanced and high-precision spatiotemporal imaging of microRNA in living cells
Biosensors and Bioelectronics · 2024-09 · 259 · 116416
DOI: 10.1016/j.bios.2024.116416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-09. Verfasst von Yuchen Song und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Sciences, Shanghai University, Shanghai, 200444, PR China. Hauptthemen laut MEDLINE: Graphite, MicroRNAs, Biosensing Techniques, Nanocomposites. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The low abundance, heterogeneous expression, and temporal changes of miRNA in different cellular locations pose significant challenges for both the detection sensitivity of miRNA liquid biopsy and intracellular imaging. In this work, we report an intelligently assembled biosensor based on catalytic hairpin assembly (CHA) and aggregation-induced emission (AIE), named as catalytic hairpin aggregation-induced emission (CHAIE), for the ultrasensitive detection and intracellular imaging of miRNA-155. To achieve such goal, tetraphenylethylene-N3 (TPE-N3) is used as AIE luminogen (AIEgen), while graphene oxide is introduced to quench the fluorescence. When the target miRNA is present, CHA reaction is triggered, causing the AIEgen to self-assemble with the hairpin DNA. This will restrict the intramolecular rotation of the AIEgen and produce a strong AIE fluorescence. Interestingly, CHAIE does not require any enzyme or expensive thermal cycling equipment, and therefore provides a rapid detection. Under optimal conditions, the proposed biosensor can determine miRNA in the concentration range from 2 pM to 200 nM within 30 min, with the detection limit of 0.42 pM. The proposed CHAIE biosensor in this work offers a low background signal and high sensitivity, making it applicable for highly precise spatiotemporal imaging of target miRNA in living cells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Sciences, Shanghai University, Shanghai, 200444, PR China.
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, 200444, PR China.
- College of Sciences, Shanghai University, Shanghai, 200444, PR China. Electronic address: dmdeng@shu.edu.cn.
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, 200444, PR China. Electronic address: cfeng@shu.edu.cn.
- College of Sciences, Shanghai University, Shanghai, 200444, PR China. Electronic address: luck@shu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Song, Y., Mao, C., Zhang, W., Deng, D., Chen, H., Sun, P., Liu, M., Feng, C., & Luo, L. (2024). Catalytic hairpin assembly-based AIEgen/graphene oxide nanocomposite for fluorescence-enhanced and high-precision spatiotemporal imaging of microRNA in living cells. Biosensors and Bioelectronics, 259, 116416. https://doi.org/10.1016/j.bios.2024.116416
Vancouver
Song Y, Mao C, Zhang W, Deng D, Chen H, Sun P, et al. Catalytic hairpin assembly-based AIEgen/graphene oxide nanocomposite for fluorescence-enhanced and high-precision spatiotemporal imaging of microRNA in living cells. Biosensors and Bioelectronics. 2024;259:116416. doi:10.1016/j.bios.2024.116416
BibTeX
@article{Song2024,
author = {Song, Yuchen and Mao, Changqing and Zhang, Wenjiao and Deng, Dongmei and Chen, Huinan and Sun, Pei and Liu, Meiyin and Feng, Chang and Luo, Liqiang},
title = {Catalytic hairpin assembly-based AIEgen/graphene oxide nanocomposite for fluorescence-enhanced and high-precision spatiotemporal imaging of microRNA in living cells},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {259},
pages = {116416},
doi = {10.1016/j.bios.2024.116416}
}
EUVIMED