EUVIMEDEUVIMED entdecken
Crossref

Electrospun EU/HPMC nanofibers decorated by ZIF-8 nanoparticle as the advanced electrochemical biosensor modifier for sensitive and selective detection of c-MET cancer biomarker in human plasma sample

Fatemeh Maleki, Habib Razmi, Mohammad-Reza Rashidi, Mehdi Yousefi, Soghra Ramezani, Marjan Ghorbani

Biosensors and Bioelectronics · 2024-08 · 257 · 116319

DOI: 10.1016/j.bios.2024.116319 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-08. Verfasst von Fatemeh Maleki und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, 53714-161, Tabriz, Iran. Hauptthemen laut MEDLINE: Biomarkers, Tumor, Biosensing Techniques, Electrochemical Techniques, Nanofibers. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Azarbaijan Shahid Madani University, Tabriz University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research presents a selective and sensitive electrochemical biosensor for the detection of the mesenchymal-epithelial transition factor (c-MET). The biosensing is based on a modification of the SPCE (screen-printed carbon electrode) with the electrospun nanofiber containing eudragit (EU), hydroxypropyl methylcellulose (HPMC), and Zeolite imidazolate frameworks (ZIF-8) nanoparticles. EU/HPMC/ZIF-8 nanofibers have presented a high capability of electron transfer, and more active surface area than bare SPCE due to synergistic effects between EU, HPMC, and ZIF-8. On the other hand, EU/HPMC nanofibers provided high porosity, flexible structures, high specific surface area, and good mechanical strength. The presence of ZIF-8 nanoparticles improved the immobilization of anti-c-MET on the modified SPCE and also resulted in increasing the conductivity. By c-MET incubation on the modified SPCE, c-MET was connected to anti-c-MET, and consequently the electrochemical signal of [Fe(CN)6]3-/4- as the anion redox probe was reduced. In order to investigate the structural and morphological characteristics and elemental composition of electrospun nanofibers, various characterization methods including FE-SEM, XRD, FTIR, and EDS were used. Under optimum conditions with a working potential range -0.3-0.6 V (vs. Ag/AgCl), linear range (LR), correlation coefficient (R2), sensitivity, and limit of detection (LOD) were acquired at 100 fg/mL-100 ng/mL, 0.9985, 53.28 μA/cm2.dec, and 1.28 fg/mL, respectively. Moreover, the mentioned biosensor was investigated in a human plasma sample to determine c-MET and showed ideal results including reproducibility, stability, and good selectivity against other proteins.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biomarkers, TumorBiosensing TechniquesElectrochemical TechniquesNanofibersProto-Oncogene Proteins c-metHumansImidazolesLimit of DetectionMetal-Organic FrameworksNanoparticlesNeoplasmsZeolites

Stichwörter der Autor:innen

Cancer biomarkerElectrochemical biosensorElectrospun EU/HPMC/ZIF-8 nanofiberMesenchymal–epithelial transition factor (c-MET)Monoclonal antibodyScreen-printed carbon electrode

Substanzen

Biomarkers, TumorImidazolesMetal-Organic FrameworksProto-Oncogene Proteins c-metZeolitesMET protein, humanZIF-8 metal-organic framework

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, 53714-161, Tabriz, Iran.
  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, 53714-161, Tabriz, Iran. Electronic address: mh_razmi@yahoo.com.
  • Pharmacy Faculty, Tabriz University of Medical Science, Tabriz, Iran.
  • Department of Immunology, School of Medicine, Tabriz University of Medical Science, Tabriz, Iran.
  • Faculty of Textile Engineering, Urmia University of Technology, Urmia 5716693188, Iran.
  • Iran Polymer and Petrochemical Institute, PO Box:14965/115, Tehran, Iran. Electronic address: ghorbani.marjan65@yahoo.com.

Förderung

  • Azarbaijan Shahid Madani University
  • Tabriz University of Medical Sciences

Zitieren

APA

Maleki, F., Razmi, H., Rashidi, M. R., Yousefi, M., Ramezani, S., & Ghorbani, M. (2024). Electrospun EU/HPMC nanofibers decorated by ZIF-8 nanoparticle as the advanced electrochemical biosensor modifier for sensitive and selective detection of c-MET cancer biomarker in human plasma sample. Biosensors and Bioelectronics, 257, 116319. https://doi.org/10.1016/j.bios.2024.116319

Vancouver

Maleki F, Razmi H, Rashidi MR, Yousefi M, Ramezani S, Ghorbani M. Electrospun EU/HPMC nanofibers decorated by ZIF-8 nanoparticle as the advanced electrochemical biosensor modifier for sensitive and selective detection of c-MET cancer biomarker in human plasma sample. Biosensors and Bioelectronics. 2024;257:116319. doi:10.1016/j.bios.2024.116319

BibTeX
@article{Maleki2024,
  author = {Maleki, Fatemeh and Razmi, Habib and Rashidi, Mohammad-Reza and Yousefi, Mehdi and Ramezani, Soghra and Ghorbani, Marjan},
  title = {Electrospun EU/HPMC nanofibers decorated by ZIF-8 nanoparticle as the advanced electrochemical biosensor modifier for sensitive and selective detection of c-MET cancer biomarker in human plasma sample},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {257},
  pages = {116319},
  doi = {10.1016/j.bios.2024.116319}
}
Kostenlos starten →