EUVIMEDEUVIMED entdecken
Crossref

An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids

Yong Yang, Can Sheng, Fang Dong, Sheng Liu

Biosensors and Bioelectronics · 2024-07 · 256 · 116280

DOI: 10.1016/j.bios.2024.116280 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-07. Verfasst von Yong Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China. Hauptthemen laut MEDLINE: Extracellular Fluid, Biosensing Techniques, Wearable Electronic Devices, Needles. Die Arbeit wurde bisher 76-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring biomarkers in human interstitial fluids (ISF) using microneedle sensors has been extensively studied. However, most of the previous studies were limited to simple in vitro demonstrations and lacked system integration and analytical performance. Here we report a miniaturized, high-precision, fully integrated wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose in human ISF. A microneedle array fabrication method is proposed which enables multiple individually addressable, regionally separated sensing electrodes on a single microneedle system. As a demonstration, a glucose sensor and a differential sensor are integrated in a single sensing patch. The differential sensing electrodes can eliminate common-mode interference signals, thus significantly improving the detection accuracy. The basic mechanism of microneedle penetration into the skin was analyzed using the finite element method (FEM). By optimizing the structure of the microneedle, the puncture efficiency was improved while the puncture force was reduced. The electrochemical properties, biocompatibility, and system stability of the microneedle sensing device were characterized before human application. The test results were closely correlated with the gold standard (blood). The platform can be used not only for glucose detection, but also for various ISF biomarkers, and it expands the potential of microneedle technology in wearable sensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracellular FluidBiosensing TechniquesWearable Electronic DevicesNeedlesEquipment DesignGlucoseHumansSmartphoneBlood Glucose Self-MonitoringContinuous Glucose Monitoring

Stichwörter der Autor:innen

Continuous glucose monitoringInterstitial fluidMicroneedlesWearable sensors

Substanzen

Glucose

Autor:innen und Institutionen

  • School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China.
  • The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China. Electronic address: dongfang@whu.edu.cn.
  • School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China; The Institute of Technological Sciences, Wuhan University, Wuhan, 430072, China; School of Power and Mec…

Zitieren

APA

Yang, Y., Sheng, C., Dong, F., & Liu, S. (2024). An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids. Biosensors and Bioelectronics, 256, 116280. https://doi.org/10.1016/j.bios.2024.116280

Vancouver

Yang Y, Sheng C, Dong F, Liu S. An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids. Biosensors and Bioelectronics. 2024;256:116280. doi:10.1016/j.bios.2024.116280

BibTeX
@article{Yang2024,
  author = {Yang, Yong and Sheng, Can and Dong, Fang and Liu, Sheng},
  title = {An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {256},
  pages = {116280},
  doi = {10.1016/j.bios.2024.116280}
}
Kostenlos starten →