EUVIMEDEUVIMED entdecken
Crossref

Electrochemical biosensor using direct electron transfer and an antibody–aptamer hybrid sandwich for target detection in complex biological samples

Gyeongho Kim, Haesik Yang

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116184 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Gyeongho Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Aptamers, Nucleotide. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct electron transfer (DET) between an electrode and redox labels is feasible in electrochemical biosensors using small aptamer-aptamer sandwiches; however, its application is limited in biosensors that rely on larger antibody-antibody sandwiches. The development of sandwich-type biosensors utilizing DET is challenged by the scarcity of aptamer-aptamer sandwich pairs with high affinity in complex biological samples. Here, we introduce an electrochemical biosensor using an antibody-aptamer hybrid sandwich for detecting thrombin in human serum. The biosensor enables rapid DET through an antibody-aptamer hybrid configuration comprising (i) an antibody capture probe that provides high and specific affinity to the target in human serum, (ii) the target thrombin, and (iii) an aptamer detection probe that facilitates convenient terminal conjugation with long flexible spacer DNA and polylinker peptide containing multiple amine-reactive phenazine ethosulfate (arPES) redox labels, allowing the conjugated labels to easily approach the electrode. Rapid repeated DET using arPES-catalyzed NADH oxidation strongly enhanced the electrochemical signals. Properly sized spacer and polylinker provided low nonspecific adsorption of the aptamer probe conjugated with multiple arPESs and low interference with the binding of the aptamer probe. Methods for immobilizing thiol-terminated antibodies on Au electrodes were compared and optimized. The developed biosensor using the antibody-aptamer hybrid sandwich exhibited high sensitivity and selectivity in detecting thrombin, surpassing the limitations of an aptamer-aptamer sandwich owing to the low affinity of thrombin aptamers in human serum. The calculated detection limit of the biosensor was ∼1.5 pM in buffer and ∼2.7 nM in human serum.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAptamers, NucleotideHumansThrombinElectronsAntibodiesOxidation-ReductionElectrodesLimit of DetectionGold

Stichwörter der Autor:innen

AntibodyAptamerDirect electron transferElectrochemical biosensorMultiple redox labelsThrombin

Substanzen

ThrombinAntibodiesAptamers, NucleotideGold

Autor:innen und Institutionen

  • Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea.
  • Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea. Electronic address: hyang@pusan.ac.kr.

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Kim, G., & Yang, H. (2024). Electrochemical biosensor using direct electron transfer and an antibody–aptamer hybrid sandwich for target detection in complex biological samples. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116184

Vancouver

Kim G, Yang H. Electrochemical biosensor using direct electron transfer and an antibody–aptamer hybrid sandwich for target detection in complex biological samples. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116184

BibTeX
@article{Kim2024,
  author = {Kim, Gyeongho and Yang, Haesik},
  title = {Electrochemical biosensor using direct electron transfer and an antibody–aptamer hybrid sandwich for target detection in complex biological samples},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116184}
}
Kostenlos starten →